Step 4: Connect The Logic Power Supply To The Akd Servo Drive - National Instruments PCI-7354 Getting Started

Motion controllers and akd servo drives
Table of Contents

Advertisement

1.
Connect the cable X9 DSUB connector to the AKD servo drive X9 DSUB connector.
2.
Connect the cable X8 10-pin connector to the AKD servo drive X8 10-pin connector.
Note
You can use the X7 I/O connector for additional I/O but it is not used for
connection to the NI UMI.
Step 4: Connect the Logic Power Supply to the AKD
Servo Drive
Using a UMI-7772/74
Note
You may use the same +24 V power supply to power both the UMI-7772/74
and the AKD drive. However, ensure that the power supply is capable of delivering
enough current for the application. If you require more power, connect a separate
+24 V power supply to the AKD drive X1 connector as described in this section.
1.
Connect the +24 V power supply (+) terminal to the +24V connection on the X1 3-pin
connector.
2.
Connect the +24 V power supply return (–) terminal to the GND connection on the X1 3-pin
connector. The X1 connector is connected to the UMI-7772/74 cable by the GND wire. Do
not remove this wire when connecting the +24 V power supply GND wire.
3.
Connect the cable X1 3-pin connector to the AKD servo drive X1 3-pin connector.
4.
Connect the STO input to the +24 V input, or connect it to the output of an external safety
relay or security control.
Note
The STO input must be powered by +24V for proper drive operation. If you
need to use the STO functionality connect the STO terminal and GND terminal to the
output of a safety relay or security control. The safety relay must comply with the
requirements of the SIL 2 according to IEC 61800-5-2, PL d according to
ISO 13849-1, or Category 3 according to EN-954. Refer to the AKD Installation
Manual for more information.
16 | ni.com | Getting Started with NI 7340/7350 Controllers and AKD Drives