4.3.2

Transport and Storage Conditions

Components in original packaging
The following specifications apply to components in transport packaging:
Standard / class
Temperature range
Temperature change
Relative humidity
Permissible change of the rel‐
ative humidity
A direct change between the specified temperatures in the air is assumed
*)
Table 4-2
Vibratory load:
● Operation (3M1)
● Package (1M2)
Shock load:
● Operation (3M1)
Product packaging
4.3.3

Operating Conditions

Note
Before commissioning components with display, remove the foil which is used to protect the
components during transport.
Climatic environmental conditions of PPU 1740-1500 and PPU 1740-1900
Parameters
Limit temperatures at 100% load
Temperature change
Humidity
Permissible change of the relative humidity
PPU 1740
Equipment Manual, 01/2019, A5E47615272B AA
Transport
EN 60721-3-2
-20 ... + 60 °C
-40 °C/+30 °C and +70 °C/+15 °C
5 ... ~95%
Transport values for PPU
9 - 29 Hz: 0.3 mm; 29 - 200 Hz: 1g
5 - 9 Hz: 3.5 mm, 9 - 200 Hz: 1 g
5 g, 30 ms
1M2
4.3 Climatic and mechanical environmental conditions
Storage
EN 60721-3-1
-25 ... + 55 °C
< 0.5 K / min (≙ 30 K / h)
*)
averaged over 5 minutes
10 ... 100 %
max. 0.1% / min (≙ 6% / h)
Values
0 ... 40 °C (front)
0 ... 45 °C (rear)
< 0.5 K / min (≙ 30 K / h) averaged over 5 minutes
Relative: 5 ... 90 %
max. 0.1%
min (≙ 6% / h)