Coupling - Gardner Denver Elmo Rietschle C Series Original Operating Instructions

Vacuum pump
Hide thumbs Also See for Elmo Rietschle C Series:
Table of Contents

Advertisement

7.2.3 Coupling

Fig. 11 Coupling
k
Coupling sprocket
m
Motor
n
Fan housing
2
q
Coupling half on the motor side
s
Screws
5
v
Fan
m
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
s
5
v
q
k
The coupling sprocket (Fig. 11/k)) is subject to wear
and must be checked regularly (at least once a year).
CAUTION
Defective coupling sprocket
Defective sprockets may lead to the rotor shaft
breaking.
To check the coupling switch the motor (Fig. 11/m)
off and ensure that it cannot be switched on again.
Undo the screws (Fig. 11/s
Remove the motor with the coupling half on the
motor side (Fig. 11/q) from the fanhousing (Fig. 11/
n
) axially and suspend using a lifting tool. If the
2
sprocket (Fig. 11/k) is damaged or worn, then re-
place it. The fan (Fig. 11/v) should also be checked
for damage from time to time and replaced if neces-
sary.
NOTICE
Frequent starting up and high ambient tem-
perature
The service life of the sprocket (Fig. 11/k) is re-
duced.
Re-assemble in reverse order.
Maintenance and repair
n
2
) on the motor flange.
5
|
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elmo rietschle c-vlr 301 vsd

Table of Contents