Checking The Rotation Direction; Post-Run - Gardner Denver Elmo Rietschle C Series Original Operating Instructions

Vacuum pump
Hide thumbs Also See for Elmo Rietschle C Series:
Table of Contents

Advertisement

6.1.1 Checking the rotation direction

6.1.2 Post-run

The intended direction of rotation of the drive
shaft is shown by the rotary direction arrow
(Fig. 2/O).
a) Start the motor briefly (max. two seconds) to
check the direction of rotation. When looking at
the motor fan, it must rotate anti-clockwise.
NOTICE
Incorrect direction of rotation
Operating in the wrong direction of rotation leads
to damage to the machine.
For removing accrued dampness and impurities out
of the pump we recommend, let the vacuum pump
post-run with 700 mbar (abs.) approximately 15 to
30 minutes.
Condensate formation and impurities
By heightened condensate formation and impurities
after shutdown of the machine deposits can adhere
to rotors as well as compressor housing and prevent
an starting when restart.
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Commissioning and decommissioning
CAUTION
19
|

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elmo rietschle c-vlr 301 vsd

Table of Contents