7.2.2 Air filtering

Mesh filter (C-VLR 301 (F001))
Fig. 7 Air filtering
D
Suction flange
f
Mesh filter
1
s
Screws
1
1
Fig. 8 Blowing out the mesh filter
1
Mesh filter
2
Compressed air
s
1
NOTICE
Insufficient maintenance on the air filter
The power of the machine lessens and damage may
occur to the machine.
The mesh filter (Fig. 7/f
out or purging or replaced more or less often de-
pending on how dirty the discharged medium is.
Remove the suction flange (Fig. 7/D) after undoing
the screws (Fig. 7/s
Also check the valve seating for contamination.
Assemble in reverse order.
Risk of injury when handling compressed air
When blowing through with compressed air, solid
particles may be carried along or powder dust swir-
ling around may cause injury to the eyes.
Therefore, when cleaning with compressed air always
wear goggles and a dust mask.
2
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Maintenance and repair
f
D
1
) must be cleaned by rinsing
1
).
1
WARNING