Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Gardner Denver Manuals
Water Pump
Elmo Rietschle C-VLR 301
Operating instructions manual
Gardner Denver Elmo Rietschle C-VLR 301 Operating Instructions Manual
Vacuum pump
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
page
of
28
Go
/
28
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Foreword
Principles
Target Group
Supplier Documentation and Accompanying Documents
Abbreviations
Directives, Standards, Laws
Symbols and Meaning
Technical Terms and Meaning
Copyright
Safety
Warning Instruction Markings
General
Designated Use
Unacceptable Operating Modes
Personal Qualifications and Training
Safety-Conscious Work
Safety Notes for the Operator
Safety Instructions for Installing, Commissioning and Maintenance
Guarantee Conditions
Transport, Storage and Disposal
Transportation
3.1.1 Unpack and Check the Delivery Condition
Lifting and Transporting
Storage
3.2.1 Ambient Conditions for Storage
Disposal
Set up and Operation
Setup
Data Plate
Description
Areas of Application
Installation
Preparing for Installation
Connecting Pipes
Filling with Lubricating Oil
Connecting the Motor
Commissioning and Decommissioning
Commissioning
6.1.1 Checking the Rotation Direction
6.1.2 Post-Run
Decommissioning/ Storing
Re-Commissioning
Maintenance and Repair
Ensuring Operational Safety
Maintenance Work
Changing the Oil
7.2.2 Air Filtering
Coupling
Repair/ Service
Spare Parts
Malfunctions: Causes and Elimination
Technical Data
Advertisement
Quick Links
1
Maintenance and Repair
Download this manual
Edition: 1.1 · 20.7.2017 · BA 885-EN
Original Operating Instructions
C-VLR 301
Vacuum pump
C-Serie
C-Series
Klaue
Claw
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for Gardner Denver Elmo Rietschle C-VLR 301
Water Pump Gardner Denver Elmo Rietschle C-VLR 401 VSD Original Operating Instructions
Vacuum pump (30 pages)
Water Pump Gardner Denver Elmo Rietschle C-VLR 1000 VSD Operating Instructions Manual
Dry running claw vacuum pump (56 pages)
Water Pump Gardner Denver Elmo Rietschle prematic C Series Operating Instructions Manual
Vacuum pump (90 pages)
Water Pump Gardner Denver Elmo Rietschle C-VLR 60 Manual
Vacuum pump (34 pages)
Water Pump Gardner Denver Elmo Rietschle C Series Original Operating Instructions
Vacuum pump (30 pages)
Water Pump Gardner Denver Elmo Rietschle C-VLR 62 Operating Instructions Manual
Vacuum pump (32 pages)
Water Pump Gardner Denver Elmo Rietschle G Series Operating Instructions Manual
(44 pages)
Water Pump Gardner Denver Elmo Rietschle V Series Original Operating Instructions
Vacuum pump (32 pages)
Water Pump Gardner Denver Elmo Rietschle VLV Series Instruction And Service Manual
Vacuum pumps (16 pages)
Water Pump Gardner Denver Elmo Rietschle V-VWZ Series Instruction And Service Manual
Fresh oil lubricated rotary vane vacuum pumps (34 pages)
Water Pump Gardner Denver Elmo Rietschle V-VTE Series Operating Instructions Manual
Vacuum pump (52 pages)
Water Pump Gardner Denver Elmo Rietschle V-VC 40 Original Operating Instructions
(32 pages)
Water Pump Gardner Denver Elmo Rietschle V-VTR 100 Original Operating Instructions
(32 pages)
Water Pump Gardner Denver Elmo Rietschle V-VC 202 Manual
Vacuum pumps (16 pages)
Water Pump Gardner Denver Elmo Rietschle V-KTR 100 Operating Instructions Manual
(32 pages)
Water Pump Gardner Denver Elmo Rietschle twister S Series Operating Instructions Manual
Vacuum pump (36 pages)
Summary of Contents for Gardner Denver Elmo Rietschle C-VLR 301
Page 1
Edition: 1.1 · 20.7.2017 · BA 885-EN Original Operating Instructions C-VLR 301 Vacuum pump C-Serie C-Series Klaue Claw...
Page 2: Table Of Contents
Re-commissioning ............www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 3
Technical Data ............. . www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 4: Foreword
Supplementary sheet C-VLR 301 (40) M 34 Abbreviations Fig. Figure C-VLR Vacuum pump Suction capacity mbar (abs.) Final vacuum, operating vacuum Corrosion protective coating Directives, standards, laws See Conformity Declaration www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 5: Symbols And Meaning
EN ISO 3744. Copyright Passing on or copying this document, using and providing information on its contents are prohibited unless expressly permitted. Contraventions will lead to claims for damages. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 6: Safety
This applies for example to: • Symbols for connections • Data and motor data plate • Instruction and warning plates The operator is responsible for observing local regu- lations. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 7: Designated Use
• installing in environments that are at risk of ex- plosions • using the machine in areas with ionising radia- tion • modifications to the machine and accessories www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 8: Personal Qualifications And Training
Risks arising from electrical energy must be eliminated. • The machine must not be in touch with inflam- mable substances. Danger of fire by hot surfaces, discharge of pumped media or cooling air www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 9: Safety Instructions For Installing, Commissioning And Maintenance
Operation by insufficiently qualified staff • Using spare parts that have not been approved by Gardner Denver Schopfheim GmbH • Unauthorised modifications to the machine or the accessories supplied by Gardner Denver Schopfheim GmbH www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 10: Transport, Storage And Disposal
(Fig. 1/3) on the transport shackle (Fig. 1/2) firmly. b) The machine must be suspended on the eye- bolt and the transport shackle using the lifting device. Fig. 1 Lifting and transporting Eyebolt Transport shackle Fixing screw www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 11: Storage
Parts subject to wear and tear (marked as such in the spare parts list) are special waste and must be disposed of in accordance with the national and local waste laws. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 12: Set Up And Operation
Condensate drain (only with version “XD”) Data plate Suction flange Direction of rotation arrow Cooling air inlet Drive motor Cooling air outlet Motor data plate Oil filling point hot surfaces > 70 ° C www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 13: Data Plate
If it is installed in the open air the unit must be protected from environmental influences, (e.g. by a protective roof). www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 14: Installation
It is possible to install the machine on a firm base without anchoring. When installing on a sub- structure we recommend fixing with flexible buffers. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 15: Connecting Pipes
Fill the lubricating oil (for suitable types see “Maintenance”) for the gear wheels and oil fill- ing point (Fig. 2/H) up to the middle of the sight glasses (Fig. 2/I). b) Close the oil filling point. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 16: Connecting The Motor
The conditions at the installation location must match the information on the motor data plate. Without derating the following is permissible: • ± 5% Voltage deviation • ± 2% Frequency deviation www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 17: Commissioning And Decommissioning
When spending a long time in the vicinity of the running machine use ear protectors to avoid permanent damage to your hearing. NOTICE Wait until the machine stops The machine must only be switched on again after it stops. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 18: 6.1.1 Checking The Rotation Direction
Design “XD”: Drain the condensate from the silencer (Fig. 2/B regularly and depending on the application. Do not drain when machine is at operating tem- perature! www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 19: Decommissioning/ Storing
Section 3.2.1, Page 11 Re-commissioning a) Check the condition of the machine (cleanliness, cabling etc.). For installation see Section 5 Page 14 For commissioning see Section 6.1 Page 17 www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 20: Maintenance And Repair
20.000 h Changing the oil 7.2.1 depending on how dirty the Clean intake air filter 7.2.2 discharged medium is. at least once a year Check for coupling wear 7.2.3 www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 21: Changing The Oil
Designation as per DIN 51502: CLP HC 150. We recommend the following oil brand: GEAR- LUBE 150 or equivalent oils by other manufacturers (also see oil recommendation plate (Fig. 4/M)). www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 22: 7.2.2 Air Filtering
Therefore, when cleaning with compressed air always wear goggles and a dust mask. Fig. 6 Blowing out the mesh filter Mesh filter Compressed air www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 23: Coupling
NOTICE Frequent starting up and high ambient tem- perature The service life of the sprocket (Fig. 7/k) is re- duced. Re-assemble in reverse order. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 24: Repair/ Service
The declaration of harmlessness is part of the supplier‘s documentation. b) After a repair or re-commissioning, the actions listed under „Installation“ and „Commissioning“ must be carried out as for initial commissioning. Fig. 8 Clearance certificate 7025.003.17 www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 25: Spare Parts
The use of other parts may lead Fig. 9 Spare parts list (example) to malfunctions and invalidate liability or the gua- rantee for any consequences arising. Fig. 10 Web site http://www.service-er.de www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 26: Malfunctions: Causes And Elimination
Deposits on the rotary piston Clean the working space and Elmo Rietschle an abnormal noise the rotary piston Service Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated. www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 27: Technical Data
D 890 ¦ C-VLR 301 • Download the pdf file http://www.gd-elmorietschle.com ¦ Downloads ¦ Product Documents ¦ C-Series ¦ Data Sheets NOTICE Subject to technical changes. Fig. 11 Data sheet (example) www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH...
Page 28
Gardner Denver Schopfheim GmbH Johann-Sutter-Straße 6+8 79650 Schopfheim · Germany Phone +49 7622 392-0 +49 7622 392-300 Elmo Rietschle is a brand of Gardner Denver‘s Industrial Products Division and part of Blower Operations.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL