For Your Safety; General Provisions For The User; General Provisions For The Maintenance Personnel - Viessmann GALILEI Tecto CI2 User Manual

Table of Contents

Advertisement

1. For your safety

Units running with flammable refrigerant R290 (Propane)
The final user and the personnel in charge of maintenance and/or technical interventions should read and

1.1 General provisions for the user

The units running with R290 are identified by a specific tag applied on the base sidewall. The type and quantity
of the refrigerant are given on the serial number plate of the unit.
Caution! Do not damage the refrigerating circuit.
Caution! Do not keep explosive substances (such as aerosol cans) with flammable propellant inside the unit.
Caution! Do not use mechanical devices or other systems to speed up the defrost process, unless they are
recommended by the manufacturer.
Caution! Do not use electric appliances in the display area, unless they are recommended by the manufacturer.
Caution! Do not exceed the load limits of display decks and shelves, as given in the section "General Data and
Features".
Caution! Do not obstruct the ventilation openings along the external perimeter of the unit.
Caution! In case the cable or the plug are damaged, call the maintenance personnel for the replacement.

1.2 General provisions for the maintenance personnel

R290 refrigerant is a class A3 ANSI/ASHRAE gas. It is highly flammable and it ignites very easily. It can in-
stantly burn with explosive effects.
The R290 refrigerant dispersed in air may lead to a fire risk or explosion in presence of free flame and/or
sparks generated by electric devices.
Maintenance and servicing are exclusively reserved to qualified personnel with a professional certificate, is-
sued by a certified body that certifies the following:
- the expertise to work on refrigerating circuits operating with R290 as a refrigerant.
- the expertise to handle safely type HC refrigerants (i.e. Hydrocarbon, to which R290 belongs) according to the
EN13313:2011.
Maintenance shall be carried out considering the risks mentioned above: do not use electric tools and open
flame.
Components which require replacement: use only original spare parts which are certified to operate in refrigera-
tion circuits working with R290.
Cod. 80005780a - GB
properly understand these instructions before using the unit.
5
01.02.2021

Advertisement

Table of Contents
loading

Table of Contents