Viessmann GALILEI Tecto CI2 User Manual page 13

Table of Contents

Advertisement

3. Rating plate
Meaning of the rating plate fields
1
Model and length of the refrigerated cabinet
2
Serial number, code and/or configuration number (if any)
3
Year of manufacture
Climate class, it gives the proper environmental conditions in which the unit operates properly
4
3 – The unit is suitable for operating in an environmental temperature of 25° C and a relative humidity of 60%
4 – The unit is suitable for operating in an environmental temperature of 30° C and a relative humidity of 55%
Temperature class of the unit; it indicates the category of the products that can be preserved in the refrigerated
cabinet:
L1: suitable for the preservation of frozen food or ice-cream
M0: suitable for the preservation of fresh products such as meat and poultry
5
M1: suitable for the preservation of fresh products such as meat and poultry
M2: suitable for the preservation of fresh products such as salami and dairy products
H: suitable for the preservation of fresh products such as fruit and vegetables
S: suitable for the preservation of products with a special classification
Maximum power absorbed by the unit, with all required accessories installed, operating in the temperature
6
class for which the units were built (given by the temperature class)
Power absorbed during defrost; includes the electric heater (if present) and all the other electric devices operat-
7
ing during the defrost cycle, such as controllers, fan motors, lighting etc.
8
Rated supply voltage, number of phases and frequency to which the cabinet must operate.
9
Electrical power absorbed, rated voltage and current of other installed electric devices (if any).
10
Electrical power absorbed, rated voltage and current of the defrost heaters (if any)
11
Electrical power absorbed, rated voltage and current of the demisting heaters (if any)
12
ID name in the EPREL database
13
Type and quantity of used refrigerant
14
It indicates the kind of lamination device. CT = capillary tube. TVX = thermostatic valve
15
Net volume of the additional refrigerant storage (if any)
16
Refrigerated display area available to display the goods
17
Maximum operating pressure inside the refrigeration circuit of the unit
18
Rated current absorbed by the unit in normal operating conditions
19
Rated current absorbed by the unit at the compressor starting phase (starting current)
20
Model of condensing unit or compressor installed
21
Electrical power absorbed, rated voltage and current of the lighting system (if any)
22
Electrical power absorbed, rated voltage and current of the fan motors (if any)
23
Electrical power absorbed, rated voltage and current of the condensing unit
Cod. 80005800a - GB