8. Dixell XR50CX control panel
Attention: The cabinet is equipped with a digital thermometer positioned inside the display area, usually close
to the front glass. The displayed temperature corresponds to the temperature in the refrigerated cabinet; there-
fore refer to this value for preserving the goods properly. The temperature displayed by the controller corre-
sponds to the set point value. For technical reasons, the temperature values provided by the two displays (i.e. ther-
mometer in the refrigerated cabinet and controller display), even if related to one another, could be different and vary
during the cabinet's operation. This fact is not an anomaly or a technical fault. To modify the working temperature, it is
necessary to consider the temperature displayed by the digital thermometer inside the refrigerated cabinet, and
then increase/decrease to the set point value memorized by the controller.

8.4 User interface

Pos.
1
2
3
4
5
6
LED
°C
°C
Cod. 80005850a - GB
1
2
3
Keys
AUX
To switch on and off the lighting (if any)
/
To start manual defrost
SET
To display or modify the set point
UP arrow— to increase the set point value
DOWN arrow— to decrease the set point value
Stand-by of the cabinet (function disabled)
MODE
ON
Compressor enabled
Flashing
Compressor in waiting mode (delayed start)
Defrost in progress
ON
Flashing
Dripping phase in progress
ON
Temperature alarm
ON
Continuous cycle running
ON
Measurement unit of temperature
Flashing
Programming phase (for maintenance technicians only)
Function
Function
26
4
5
6
01.02.2021