5. Setting up the unit

5.4 Cleaning before starting

Before connecting the unit to the power supply, remove the protective films and clean both the internal and external
surfaces of the refrigerated cabinet, in particular the display decks. It is recommended that you use lukewarm water
and neutral detergents (pH 6÷8).
Do not use hoses connected to the water system to clean the unit. Do not use direct or indirect water jets or
pressurized cleaning machines (i.e. high pressure washers).
Do not use alcohol, abrasive pads or solvents to clean the unit. After cleaning, dry the parts immediately with a
soft cotton cloth. For further details and information about cleaning, please see Chapter 7 "User's maintenance".

5.5 Electric connection and power up __________________________________

The power supply to which the cabinet is going to be connected must comply with the regulations in force in the
country where the unit is installed. The frequency and voltage rating of the power supply must correspond with the
values given on the identification plate of the refrigerated cabinet. Before switching on the unit, make sure that the
voltage rating matches the one required and is within the allowed tolerance limits (±10%).
It is mandatory to ground the refrigerated cabinet. Efficient grounding is essential for safety.
Upstream of the socket, it is recommended to have the installation of an omni-polar power isolator switch, with
air gap between the contacts of at least 3 mm. This measure is to be considered mandatory if the connected load ex-
ceeds 1000W, or if the unit is connected directly to the power supply without using a plug (e.g. cabinet without con-
densing unit and connected to an external refrigeration unit). The power isolator switch should be a magnetothermal
switch with high sensitivity differential circuit breaker.
Do not use time-based devices to switch on-off. Do not connect the unit to cyclical on and off switching circuits.
Do not use extension cords, adaptors and multiple sockets. Do not bend, twist, stress or squeeze the cord and
avoid it touches hot surfaces or sharp edges.
If the cable is damaged, ask the Technical Support or a qualified technician to replace it. Use an original spare
part.
If the socket does not match the plug, ask a qualified technician for a replacement of the socket.
Before inserting the plug into the socket, make sure that the main power switch of the unit (magnetothermal
switch) is in OFF position. Insert the plug into the socket and switch on the unit. If the unit is not used for a long time,
switch off the power switch and pull out the plug.