6. Loading and using the unit

6.3 Temperature setting

Setting-up working parameters: for adjusting the "set-point" temperature and the other parameters, see the in-
structions of the control panel included in this manual. When setting up the set-point, make sure that the resulting tem-
perature in the cabinet matches the temperature class of the cabinet and/or the displayed product. Setting up a tem-
perature that is too low may obstruct the evaporator and create an excessive formation of frost.

6.4 Defrost

__________________________________________________
The units are equipped with an automatic system for the cyclic defrost of the evaporator. This system is
managed by the electronic controller of the control panel. Defrost parameters are pre-set at the factory according the
needs of each unit. In particular cases, it may be necessary to manually start a defrost cycle by using the electronic
controller (see the instructions about the electronic controller given in this manual). Manual defrost will have to be acti-
vated whenever a loss or a reduction of air flow is detected at the air-discharge grill. This condition occurs when the
evaporator is clogged by frost that prevents air from circulating properly. If there is massive or a rapidly developed for-
mation of frost inside the evaporator that requires frequent manual defrost operations, it means that the environmental
conditions where the unit is working are not suitable or that the goods are not properly positioned in the unit.
During closing time or holidays, it is recommended to use "night blinds" or "night covers" (both of them are op-
tional accessories). This measure provides a substantial reduction of energy consumption and a better preservation of
the products.
.

6.5 Correct use of the unit ____________________________________________

The unit cannot be used by people, including children, whose physical, sensorial or mental capacities are im-
paired, or by people who are not properly trained, unless they are supervised by a person responsible for their safety
who has explained them the correct and safe use of the
The unit is used in places open to public. Make sure children are supervised to avoid that they play with the
unit.
It is striclty forbidden to use
Avoid to overload display decks of the unit as well as its shelves and top canopy. Follow the loading limits given
in this manual (see chapter 2 "General data and features").
For units working with R290 as refrigerant, which is flammable, refer to the safety warnings given in the chap-
ter "For your safety" at the beginning of this
Cod. 80006370a - GB