Tp 4000 Cel / Tp 5000 Cel Power Source - Fronius Trans Pocket 4000 CEL Operating Instructions/Spare Parts List

Mma power source
Table of Contents

Advertisement

Available languages

Available languages

Displayed service
Err | 052
codes
(continued)
Cause:
Remedy:
Err | PE
Cause:
Remedy:
Err | bPS, Err | IP, dSP | Axx
dSP | Cxx, dSP | Exx, dSP | Sy
dSP | nSy
Cause:
Remedy:
r
Cause:
Remedy:
r
Cause:
Remedy:
r
Cause:
Remedy:
TP 4000 CEL / TP
Power source does not function
5000 CEL power
Mains switch is ON, but indicators are not lit up
source
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Mains overvoltage: Mains voltage has risen above the tolerance range (+/-
15%)
Check mains voltage
The earth-fault current watchdog has triggered the power source's safety
cut-out.
Switch off the power source, wait for 10 seconds and then switch on
again. If you have tried doing this several times and the error continues to
occur - contact After Sales Service.
The earth-fault current watchdog has triggered the power source's safety
cut-out.
Switch off the power source, wait for 10 sec. and then switch on again. If
you have tried doing this several times and the error con-tinues to occur -
contact After Sales Service.
| E30
r-Adjustment: There is no contact with the workpiece
Connect up the earth cable; ensure a tight connection between the electro-
de holder and the workpiece
| E31
r-Adjustment: Procedure has been interrupted by repeated pressing of the
Setup / Store (7) button
Ensure a tight connection between the electrode holder or chuck for the
tungsten electrode and the workpiece – press the Setup / Store (7)
| E33, r
| E34
r-adjustment: Poor contact between electrode holder or chuck for tungsten
electrode and workpiece r-Abgleich: Schlechter Kontakt zwischen Elektro-
denhalter bzw. Spannkörper für Wolframelektrode und Werkstück
Clean the point of contact, clamp electrode holder or chuck for tungsten
electrode firmly, resp. press down on the workpiece, check earth connec-
tion
Break in mains lead, mains plug not plugged in
Check mains supply lead, make sure mains plug is plugged in
Mains fuse is faulty
Change mains fuse
Mains outlet socket or plug is faulty
Change faulty components
32