Troubleshooting

General remarks

The digital power sources are equipped with an intelligent safety system. This means
that there was no need for any melting-type fuses at all. After a possible malfunction or
error has been remedied, the power source can be put back into normal operation again
without any fuses having to be changed.
Displayed service
codes
tP1 | xxx, tP2 | xxx, tP3 | xxx
tP4 | xxx, tP5 | xxx, tP6 | xxx
(xxx stands for a temperature indication)
Cause:
Remedy:
tS1 | xxx, tS2 | xxx, tS3 | xxx
(xxx stands for a temperature indication)
Cause:
Remedy:
tSt | xxx
(xxx stands for a temperature indication)
Cause:
Remedy:
Err | 049
Cause:
Remedy:
Err | 051
Cause:
Remedy:
WARNING! An electric shock can be fatal. Before opening up the machine
-
Switch the mains switch to the - O - position
-
Unplug machine from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-
Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have been discharged
CAUTION! Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
grounding (earthing) the housing and must NOT be replaced by any other
screws that do not provide a reliable PE conductor connection.
NOTE! If any other error message appears on the displays, which is not descri-
bed here, then the fault is one that can only be put right by a service technician.
Make a note of the error message shown in the display, and of the serial
number and configuration of the power source, and get in touch with our after-
sales service with a detailed desrciption of the error.
Over-temperature in primary circuit of power source
Allow the power source to cool down
Over-temperature in secondary circuit of power source
Allow the power source to cool down
Over-temperature in the control circuit
Allow the power source to cool down
Phase failure
Check mains fuse protection, mains supply lead and mains plug
Mains undervoltage: Mains voltage has dropped below the tolerance range
(+/- 15%)
Check mains voltage