Control Unit Display - Vent-Axia Sentinel Kinetic Operation Manual

Mechanical ventilation/heat recovery (mvhr)
Hide thumbs Also See for Sentinel Kinetic:
Table of Contents

Advertisement

Product Description

Control Unit Display

The Control Unit is located at the front of the Sentinel Kinetic unit. The Control Unit provides the user interface
for commissioning and monitoring purposes.
Figure 2: Control Unit
Display
The main display is an LCD with automatic backlight,
which is turned off to minimise power consumption
when the unit is operational (see Overview on page 8).
Buttons
Four buttons on the Control Unit provide the controls for configuring and monitoring the unit.
Table 1: Control Unit Buttons
Button
N.B Additional airflow modes are available from the
start-up screens see Appendix One for further details.
Sentinel Kinetic MVHR Operation & Monitoring
Function
Press to adjust settings and press to save settings.
Press to go to the above screen or to increase a parameter value. Press
and hold for more than 2 seconds for fast scrolling.
Press to go to the next screen or to decrease a parameter value. Press and
hold for more than 2 seconds for fast scrolling.
Press to activate Boost mode.
No. of presses
1
2
3
4
Press and hold for 5 seconds to activate Purge mode. (Press and hold for
5 seconds to cancel Purge).
Normal Airflow
30%
Boost action
(Control Mode 01)
Boosts for 30 minutes
Boosts for 60 minutes
Boosts continuously
Back to Normal flow rate
button when Control Mode 02 is selected in the
5