Stick On Label; Pressure Testing - Rangemaster MCY 1200 Dual Fuel User's Manual & Installation Instructions

Table of Contents

Advertisement

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have nished.

Stick on Label

Stick the appropriate label on to the data badge to indicate
the gas the appliance is now set for.

Pressure Testing

The gas pressure can be checked at the pressure test point
on the gas inlet pipe (Fig.9-7). Remove the screw using a
spanner. Fit a suitable pressure measuring device to the end
of the test pipe using tubing.
Turn on and light one of the hotplate burners.
See the data badge for test pressures - located adjacent to
the gas hose.
Turn o the burners and remove the pressure gauge.
Re t the screw and tighten.
Check the appliance is gas sound.
n
n
Check the operation of all the burners.
n
n
32
Fig.9-7

Advertisement

Table of Contents
loading

Table of Contents