6 Installation Guide

This chapter helps users correctly install and safely use Switches.

6.1 Installation Precautions

Precautions: To avoid equipment damage and personal injury, observe
the following precautions:
The Switch room should be dry and ventilated, free from corrosive
gases and strong electromagnetic interference.
The humidity of the Switch equipment room should be 5% to 95%.
Install proper equipment if possible.
The grounding of the Switch shall comply with the grounding
requirements described in this manual, and shall be separately
and well grounded.
Keep a proper distance between the Switch and other devices. Do
not stack other devices with the Switch.
The connection cable between the Switch and the distribution
frame should be standardized and reasonable, and the
distribution frame (box) jumper wire should be concise and clear
to prevent the phenomenon of parallel lines and wires.
To avoid the danger of electric shock, do not open the chassis
without authorization; If any fault occurs, contact professional
maintenance personnel.
Safety Tips:
Ensure that the PGND cable of the power socket is properly
grounded;
Ensure sufficient space for heat dissipation and ventilation of the
Switch. Do not place heavy objects on the Switch.