Download Print this page

Emerson Rosemount 702 Quick Start Manual page 50

Wireless discrete transmitter
Hide thumbs Also See for Rosemount 702:

Advertisement

Quick Start Guide
Discrete input
sensor terminal
U
= 6.6 V
O
I
= 26.2 mA
O
P
= 42.6 mW
O
C
= 10.9 µF
O
L
= 500 µH
O
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To
avoid electrostatic charge build-up, it must not be rubbed or
cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module, MHM-89004 Blue Power
Module, or Intelligent Power Module 71008 may be replaced
in a hazardous area. The Power Modules have a surface
resistivity greater than 1 GΩ and must be properly installed
in the wireless device enclosure. Care must be taken during
transportation to and from the point of installation to prevent
electrostatic charge build-up.
8.9
International
8.9.1  I7 IECEx Intrinsic Safety
Certificate:
Standards:
Markings:
Sensor terminal
parameters (option
code 32)
U
= 6.51 V
O
I
= 13.37 mA
O
P
= 21.76 mW
O
C
= 0.216 µF
i
C
= 23.78 µF
O IIC
50
Hydrocarbon
sensor
transmitter
output
U
= 7.8 V
o
I
= 92 mA
o
P
= 180 W
o
C
= 10 F
i
L
= 0
i
IECEx BAS 07.0082X
IEC 60079-0: 2017, IEC 60079-11: 2011
Ex ia IIC T4 Ga, T4(-60 °C ≤ T
Ex ia IIC T5 Ga, T5(-60 °C ≤ T
Fuel sensor terminal
parameters (option
code 61)
U
= 7.8 V
O
I
= 92 mA
O
P
= 180 mW
O
C
= 10 nF
i
C
= 9.2 µF
O IIC
Discrete Input
transmitter rev
2 output
U
= 6.6 V
O
I
= 13.4 mA
O
P
= 21.8 W
O
Ci= 0.216 nF
L
= 0
i
≤ +70 °C)
a
≤ +40 °C)
a
Plunger arrival
transmitter
parameters (option
code 52)
U
= 6.6 V
O
I
= 125 mA
O
P
= 202 mW
O
C
= 8.36nF
i
Li = 0
Emerson.com/Rosemount
July 2023
Plunger Arrival
Transmitter
Output
U
= 6.6 V
O
I
= 125 mA
O
P
= 202 mW
O
C
= 8.36 nF
i
L
= 0
i

Advertisement

loading