8. SET-UP GUIDE FOR QUASAR PCB ELECTRONICS:
Factory default program settings for QUASAR models are:
a. Units - Gallons
b. Unfiltered unit
c. Flow Rate = 1.0 GPM
d. Filter Capacity = 4750 gallons [18000 liters] for VersaFilter III
Top panel will need to be removed by taking out one screw on each side. Set aside until
programming is complete. Remove wire tie bundling pushbutton inside bottle dispenser. You
can then adjust program using the pushbutton through the top of the dispenser
To change the program settings, follow these steps:
Display
000000000
Depress button for 3 seconds to enter into the following menu settings and make changes.
BOTTLES REUSED
Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button press) and
(Home Screen)
revert back to Home Screen.
LTR/GAL
Depress button 3 seconds to change from Gallons to Liters,
GAL[LTR]
or momentary press to advance to next menu.
UNFILT/FILT?
Depress button 3 seconds to change from Unfiltered to Filtered unit,
UNFILTERED UNIT
or momentary press to advance to next menu.
[FILTERED UNIT]
SELECT RATE
To change flow rate, momentarily depress button to change whole gallon digit.
1.0 GPM UNIT
Hold button 3 seconds to advance to TENTHS of gallon digit.
[3.8 LPM UNIT]
Depress momentarily to change the digit.
Hold button 3 seconds to advance to the next menu.
RESET
00000000
Depress button for 3 seconds to reset water usage count,
GALLON COUNT?
or momentary press to advance to next menu.
[LTR COUNT?]
FILT CAPAC
Depress button for 3 seconds to change filter capacity to 1250 GAL [5000 LTR] for VersaFilter I.
OF 4750 GAL
Depress button for 3 seconds to change filter capacity to 3000 GAL [11000 LTR] for VersaFilter II.
[18000 LTR]
Depress button for 3 seconds to change filter capacity to 4750 GAL [18000 LTR] for VersaFilter III.
or momentary press to advance to next menu.
3 sec rule ?
Depress button for 3 seconds to switch from 3 sec rule to 0.5L bottle,
3 sec
or momentary press to advance to next menu.
[0.5L]
(The 3 sec rule increases the bottle count by 1 if the water is dispensed for 3 sec or more. When .5L is
selected, the bottle count will advance based on .5L volumes dispensed using FLOW RATE and
dispense time to calculate total volume dispensed.)
RESET
00000000
Depress button for 3 seconds to reset BOTTLES REUSED count to zero (Home Screen),
BOT COUNT?
or momentary press to advance to next menu.
Bot Filler
Depress button for 3 seconds to change maximum dispense time to 10, 20 or 30 seconds,
Set time: 20 s
or momentary press to advance to next menu.
Override Stop
Depress Button 3 sec to change from "N" to "Y". Allow the menu to return to the home screen –
Dispense: N
approximately 10 seconds. ( If the Quasar fails, the water will not dispense when "N" is selected. If
"Y" is selected, water can still dispense if Quasar fails. )
P/N 030099-709, 3/2023
©2023 LVD Acquisition, LLC; OASIS is a registered trademark of LVD Acquisition, LLC dba OASIS International.
e. Bottle Count = 3 sec rule (1 Bottle)
f. 20 second maximum dispense time
g. Override Stop Dispense: N
Pushbutton
Action
.
14