Interlock Safety Switches; Acrylic Top Lid; Side Cover; Temperature Sensor - Trotec Speedy 100 flexx Operating Manual

Table of Contents

Advertisement

First priority:
Prevention of danger to the operating personnel.
Second priority:
Prevention of damage or destruction of the machine and/or material.
ACKNOWLEDGE THE EMERGENCY STOP SWITCH
2.7.4

Interlock safety switches

Interlock safety switch query the closed status of the acrylic top lid, side panels and front door. If the safety devices are
open or not present, the laser cannot be operated. However, the pilot laser stays active.
2.7.5

Acrylic top lid

The type of acrylic top lid depends on the laser type. It protects the operator from uncontrolled emission of laser
radiation.
2.7.6

Side cover

The side panels protect from laser light and must always be closed and properly attached.
2.7.7

Temperature sensor

The temperature sensors ensure reliable temperature monitoring of the interior of the machine and are available as
additional option.
2.7.8

In case of safety device malfunction

Actual or presumed damage to the safety devices can cause injury or damage. Following measures must be carried out.
1. Turn the emergency stop switch counterclockwise to
unlock it so that the green marking is visible.
2. Restart the laser system using the key switch.