Emergency Stop Button; Interlock Safety Switches; Acrylic Top Lid; Side Cover - Trotec Speedy 360 fiber Operating Manual

Table of Contents

Advertisement

Safety
2.7.4

Emergency stop button

The Emergency stop button, which is located above the operation panel, is present only if the machine is
equipped with an optional temperature sensor.
When pressing an Emergency stop button, the electric circuit immediately shuts off.
The laser beam is interrupted, and all movements are stopped.
The function of the Emergency stop button is:
Firstly:
To prevent any risks to the operating personnel.
Secondly:
To avoid any damage to/destruction of the machine/material.
Emergency stop button acknowledge
2.7.5

Interlock safety switches

Interlock safety switch query the closed status of the acrylic top lid, side panels and front door. If the safety
devices are open or not present, the laser cannot be operated. However, the pilot laser stays active.
2.7.6

Acrylic top lid

The type of acrylic top lid depends on the laser type. It protects the operator from uncontrolled emission of
laser radiation.
2.7.7

Side cover

The side panels protect from laser light and must always be closed and properly attached.
24
1. Turn the Emergency stop button counterclockwise
to unlock it (green marker is visible).
2. Reboot the laser system to acknowledge the laser
fault.
ENGLISH (Translation)

Advertisement

Table of Contents
loading

Table of Contents