PIT es Set10u-5ns

Safety characteristic data

Operating mode
Perceptibility of red illumina-
tion in defined ambient condi-
tions
Operating mode
Perceptibility of red illumination in
defined ambient conditions
Operating mode
N/C contacts
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Please note that the Performance Level in accordance with EN 13849-1 can be reduced
because of reduced fault detection when several E-STOP devices are cascaded.
Operating Manual PIT es Set10u-5ns
1004426-EN-01
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
EN ISO 13849-1:
EN ISO 13849-1:
2015
2015
PL d
Cat. 2
B10d in accordance with EN ISO
13849-1: 2015 and EN 62061
100.000
NOTICE
Only one PIT es Set10u may be used per circuit (no cascading).
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
EN ISO 13849-1:
2015
PFH
[1/h]
D
3,00E-07
TM [year] in accordance with EN
ISO 13849-1:2015
20
EN ISO 13849-1: 2015
B10d
100.000
EN ISO 13849-1:
2015
T
[year]
M
20