Wiring

Please note:
}
Information given in the
}
The power supply must meet the regulations for PELV in accordance with EN 60204-1.
}
The maximum cable length depends on the conductor cross section used and the current
requirement of the connected evaluation device. In a maximum current consumption of
100 mA, plus the current of the input circuits of the evaluation device, a rated operating
voltage of 24 V (tolerance: -20 %/+15 %, that is at least 19.2 V) must be available.
}
Only one PIT es Set10u may be used per circuit. However, it may be cascaded with con-
ventional electromechanical E-STOP devices that have only N/C contacts. Note that
when operating a conventional E-STOP device which is in the chain before the PIT es
Set10u-5ns (AIDA), the PIT es Set10u-5ns (AIDA) is not electrically supplied and there-
fore it is not illuminated.
Operating Manual PIT es Set10u-5ns
1004426-EN-01
"Technical details [
20]" must be followed.