temperature value. After that, press "MENU/OK" button to save setting.
4.7.17 Independent Swing Function Setting
Under on status, after entering into user function page, press "˄" or "˅" button to
select the independent swing function. Press "MENU/OK" button to enter into
independent swing function setting page.
Press "˄" or "˅" button can select independent swing setting, reset independent
swing and view independent swing setting list. After that, press "MENU/OK" button to
enter into corresponding item setting page.
(1)
Once it have entered into independent swing setting page, press "˄" or "˅"
button to select the air outlet (there are four air outlet on the panel marked
by the circles. The number is 1, 2, 3 and 4. The number of "0" of air outlet is
corresponding to the number of circles of air outlet on the panel) and then
press "˂" or "˃" button to turn on or turn off the independent swing function
for this air outlet . Press "MENU/OK" button can set the detailed swing
mode for this air outlet. Press "˄" or "˅" button to set the detailed mode. The
swing mode is circulating according to the sequence in the Fig. as below.
Once setting is finished, press "MENU/OK" button to save it.
(2)
Once it has entered into the setting page of reset independent swing, press
"˂" or "˃" button to select whether reset independent swing or not. Once
Figure 4-9 Swing Setting