Page 1
Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or send an email to global@cn.gree.com for the electronic version.
Page 2
User Notice Never install the wired controller in the moist circumstance or expose it directly under the ◆ sunlight. ◆ Never beat, throw, and frequently disassemble the wired controller and the wireless remote controller. ◆ Never operate the wired controller and the wireless remote controller with wet hands. Do not remove or install the wired controller by yourself.
Contents Wired Controller XE73-44/E................1 1 Symbols on LCD ................... 1 1.1 Outside View of the Wired Controller ..............1 1.2 LCD of the Wired Controller ................. 1 2 Buttons ......................2 2.1 Buttons on the Wired Controller ................2 2.2 Function of the Buttons ..................3 3 Operation Instructions ...................
Wired Controller XE73-44/E Wired Controller XE73-44/E 1 Symbols on LCD 1.1 Outside View of the Wired Controller Fig.1 Outside View of the Wired Controller 1.2 LCD of the Wired Controller Fig.2 LCD of the Wired Controller...
Wired Controller XE73-44/E Table 1 Display Instruction of Display Automatic mode (under auto mode, the indoor unit will select its Auto operating mode according to the variation of room temperature) Cool Cooling mode Dry mode Fan mode Heat Heating mode...
Wired Controller XE73-44/E 2.2 Function of the Buttons Table 2 Name Function Function selection and cancellation. ① SWING/ENTER Setting of the up and down swing function. ② ▲ Running temperature setting of the indoor unit, range:16~30°C(61~86°F). ① Timer setting, range:0.5-24 hr.
Wired Controller XE73-44/E 3 Operation Instructions 3.1 ON/OFF Press ON/OFF to turn on the unit and turn it off by another press. Note: The state shown in Fig.4 indicates the “OFF” state of the unit after power on. The state shown in Fig.5 indicates the “ON”...
Wired Controller XE73-44/E Fig.6 3.4 Fan Setting Under the “ON” State of the unit, press Fan and then fan speed of the indoor unit will change circularly as shown in Fig.7. Auto (Low) (Medium low) (Medium) (Medium high) (High) Fig.7 3.5 Timer Setting...
Wired Controller XE73-44/E Press “TIMER” button to set Press ▲ or ▼ button to adjust time Press “TIMER” button to cancel Press “SWING/ENTER” to finish timer setting timer setting Fig. 8 Timer off Setting under the “ON” State of the Unit Timer range: 0.5-24hr.
Wired Controller XE73-44/E 3.7 Left & Right Swing Setting Swing On: Press FUNCTION under on state of the unit to activate the swing function. In this case, will blink. After that, press SWING/ENTER to make a confirmation. Swing Off: When the Swing function is on, press FUNCTION to enter the Swing setting interface, with blinking.
Wired Controller XE73-44/E 3.8 Fresh Air Function Setting Valve Turn on fresh air valve function: Under unit on status, press FUNCTION button on the panel to select “Fresh air valve” function option. When icon flashes, it enters fresh air valve setting mode. Previous temperature display position will display the level of fresh air valve.
Wired Controller XE73-44/E 3.9 Sleep Setting Sleep on: Press FUNCTION under on state of the unit till the unit enters the Sleep setting interface. Press SWING/ENTER to confirm the setting. Sleep off: When the Sleep function is activated, press FUNCTION to enter the Sleep setting interface.
Wired Controller XE73-44/E 3.10 Turbo Setting Turbo function: The unit at the high fan speed can realize quick cooling or heating so that the room temperature can quickly approach the setting value. In the Cooling or Heating mode, press FUNCTION till the unit enters the Turbo setting interface...
Wired Controller XE73-44/E 3.11 Energy Saving Function Setting Turn on energy saving function: 1)Energy Saving Setting for Cooling When the unit runs under the COOL or DRY mode, press FUNCTION button to select "SAVE" function option, with "SAVE" flashing, and then press ▲ or ▼ to adjust the lower limit, after that, press the SWING/ENTER button to activate this function.
Wired Controller XE73-44/E 3.12 E-heater Setting E-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to be will be Once the wired controller or the remote controller enters the Heating mode, this function turned on automatically. Press FUNCTION in the Heating mode to enter the E-heater setting interface and then press SWING/ENTER to cancel this function.
Wired Controller XE73-44/E 3.13 X-fan Setting X-fan function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In the Cooling or Dry mode, press FUNCTION till the unit enters the X-fan setting interface and then press SWING/ENTER to active this function.
Wired Controller XE73-44/E 3.14 Quiet Function Setting Turn on quiet function: Under unit on status, press FUNCTION button on the panel to select “Quiet” function option. When “Quiet” or “Auto quiet” flashes, it enters quiet function setting mode. Press ▲ or ▼ button to switch between “Quiet”...
Wired Controller XE73-44/E 3.15 Health Setting Health on: Press FUNCTION under on state of the unit till the unit enters the Health setting interface. Press SWING/ENTER to confirm the setting. Health off: When the Health function is activated, press FUNCTION to enter the Health setting interface.
Wired Controller XE73-44/E 3.16 Absent Setting Absent on: Press FUNCTION under on state of the unit till the unit enters the Absent setting interface. Press SWING/ENTER to confirm the setting. Absent off: When the Absent function is activated, press FUNCTION to enter the Absent setting interface.
Wired Controller XE73-44/E 3.17 I-Demand Setting I-Demand on: Press FUNCTION under on state of the unit till the unit enters the I-Demand setting interface. Press SWING/ENTER to confirm the setting. I-Demand off: When the I-Demand function is activated, press FUNCTION to enter the I-Demand setting interface.
Wired Controller XE7 -44/E 3.18 WiFi Function Setting "Gree+" APP can be used to control it. Please scan the QR code to download it. APP can only set some common functions of WiFi wired controller: ON/OFF, mode, set temperature, FAN speed, etc.
Wired Controller XE73-44/E Select the temperature sensor at the wired controller under the cooling, dry and fan modes, ④ and select the temperature sensor at the return air inlet under the heating mode and auto modes (04 displayed in the timer display area).
Page 23
Fig. 21 Note: CN1 is 485 communication interface and it used Wired Controller XE73-44/E for connecting the 4-core communication wire. These two needle stands(CN2、CN3) are used for connecting the smart zone controller. There is no sequence for these two needle stands. You can connect one or two needle stand(s) basing on the requirement.
Page 24
Wired Controller XE73-44/E For matching with different models, the patch cord and the connection wire are provided in the packaging box of wired controller. As shown in fig. 22. Fig. 22: Schematic diagram of patch cord and connection wire ● If the air conditioner has been installed with the patch cord (fig. 24) used for connecting the wired controller.
Page 25
DIP switch. There is a 2-bit DIP switch on the main board of wired controller XE73-44/E. As for the last #n wired controller in the control system, the 1-bit and the 2-bit of the DIP switch should be manually pulled to position “on” and position “off” respectively. The DIP switches of other wired controllers should be kept at the initial ex-factory status (1-bit and 2-bit are set at position “off”).
Wired Controller XE73-44/E cord and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm, otherwise the communication of the unit will probably work abnormally. If the air conditioning unit is installed where is vulnerable to electromagnetic interference, ②...
Page 27
Wired Controller XE73-44/E Table 4 Meaning of Each Error Error Error Error Error Code Code Return air temperature sensor open/short Drive board communication error circuited evaporator temperature sensor open/short Compressor overheating protection circuited Indoor unit liquid valve temperature sensor Indoor and outdoor units unmatched...
Page 28
Wired Controller XE73-44/E Table 4 Meaning of Each Error Error Error Error Error Code Code Communication error between IDU and IDU network address error grid connection Communication error between ODU and Ip address allocation overflow grid connection Main error at grid connection side...
Page 29
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com Web: www.gree.com 600005064010...