Gree XE71-42/G Owner's Manual page 25

Wired controller
Table of Contents

Advertisement

Wired Controller XE71-42/G
auto saving.
NOTE!
This function can be set only in cooling and dry mode.
4.7.10 Filter Clean Reminder Setting
After entering into user function page, press "˄" or "˅" button to select filter clean
function and press "˂" or "˃" button to turn on or turn off this function. Press
"MENU/OK" button to enter the setting page of filter clean reminder function.
After entering the setting page of filter clean reminder function, press "˄" or "˅"
button to select pollution level and then press "˂" or "˃" button to set pollution level;
press "˄" or "˅" button to select accumulating time setting and then press "˂" or "˃"
button to set required time. Once setting is finished, press "MENU/OK" button to save
the setting.
When level 1 is selected, the adjusting range of accumulating operating time is
5,500~10,000 hours, with 500 hours in each increase or decrease.
When level 2 is selected, the adjusting range of accumulating operating time is
1,400~5,000 hours, with 400 hours in each increase or decrease.
When level 3 is selected, the adjusting range of accumulating operating time is
100~1,000 hours, with 100 hours in each increase or decrease.
Whenever you turn off this function, the unit's operating time will be zero
clearing.
20