Part 3: Perform the Initial Configuration

By default, Zero touch provisioning (ZTP) starts automatically. Zero touch provisioning (ZTP) allows you to provision new
Juniper Networks devices in your network automatically, with minimal manual intervention. You can use either management
ports or network ports on your switch to connect to the network. When you physically connect a device to the network
and boot it with a default factory configuration, the device upgrades (or downgrades) the Junos OS release and autoinstalls
a configuration file from the network. For more information on ZTP, see
If you do not use ZTP, you must disable the ZTP process and then perform the following:
NOTE:
To disable the ZTP process, manually delete the auto-image-upgrade statement located in the [edit
chassis] hierarchy.
You must perform the initial configuration of the router through the console port. Before you begin, set the following
parameter values in the console server or PC:
Baud Rate—9600
Flow Control—None
Data—8
Parity—None
Stop Bits—1
DCD State—Disregard
To connect and configure the router from the console:
1. Connect the console port to a laptop or PC using the provided RJ-45 cable and RJ-45 to DB-9 serial port adapter. The
console (CON) port is located on the port panel of the router.
2. Log in as root. There is no password. If the software booted before you connected to the console port, you might need
to press the Enter key for the prompt to appear.
login: root
3. Start the command-line interface (CLI).
root@% cli
4. Enter configuration mode.
root>configure
Zero Touch
Provisioning.
4