Mounting The Clamping Block On The Base Plate - SCHUNK KSP3 Assembly And Operating Manual

Table of Contents

Advertisement

4.3 Mounting the clamping block on the base plate

05.00 | KSP3, KSP3-LH, KSP3-F | TANDEM Clamping Block | en | 1463318
(If the two parts are delivered separately)
When mounting TANDEM clamping force blocks on ABP-h plus
TANDEM base plates, use the shorter mounting screws included in
the base plate accessory kit instead of the standard mounting
screws (item 19) that come with the clamping force block.
For KSP3 100, KSP3-LH 100 and KSP3-F 100:
Use the M8 x 30 screws from the base plate accessory kit instead
of the M8 x 35 screws (item 84).
For KSP3 160, KSP3-LH 160 and KSP3-F 160:
Use the M10 x 35 screws from the base plate accessory kit instead
of the M10 x 40 screws (item 84).
For KSP3 250, KSP3-LH 250 and KSP3-F 250:
Use the M12 x 40 screws from the base plate accessory kit instead
of the M12 x 45 screws (item 84).
NOTE:
If the clamping force block and base plate are ordered
separately, the screws, O-rings and clamping sleeves for
assembling the parts are included in the accessory kit that comes
with the clamping force block.
Do not open the connections on the front of the clamping
l
force block (I, II), or seal them with suitable dummy plugs (M5
or G1/8").
Insert the clamping sleeves from the accessory pack into the
l
centering holes on the base plate.
Remove the seal plugs from the base plate (internal air feed-
l
through III, IV) and insert the O-rings from the accessory pack
into the recesses for the air feed-throughs.
Mount the clamping force block onto the base plate.
l
NOTE:
The TANDEM base plates do not have a connection possibility for
the inductive proximity switches on the TANDEM clamping force
blocks.
The function for monitoring the jaw position can only be
connected externally. When joining, make sure the air feed-
throughs for the clamping system and the base plate are
precisely aligned.
Screw the two parts together using the four screws (item 84)
l
from the accessory kit. In doing so, observe tightening
torques,
[/ 17].
} 4.1
Remove the locking screws from the pneumatic connections
l
on the base plate.
Connect the diaphragm pressure switch and set the switch to
l
the required minimum pressure.