11-Easy Going - MCZ PLASMA 75Q RH/LH WOOD Instructions Manual

Closed fireplace
Table of Contents

Advertisement

11-EASY GOING

COMBUSTION CONTROL
The new "Easy Going" air adjustment system is based on the choice of 5 types of use of the closed firebox.
PRIMARY AIR
The primary air comes in directly through the openings between the casing and the structure of the closed fireplace. This air makes
combustion possible. With the aid of the cold handle, moving the provided lever, as shown in the figure, to the right, we achieve full
opening with quicker combustion, while moving it to the left will close it and combustion will be slower.
The lever has 5 positions:
PRIMARY/SECONDARY AIR CONTROL
4
2
5
3
1
1 - START - position for quick ignition of the flame
2 - CLEAN - position for a cleaner glass
3 - COMFORT - for a lively flame with the right compromise of primary and secondary air
4 - PERFORMANCE - for better heat exchange of the fireplace
5 - SLEEP - for slower combustion without almost any oxygen
The lever turned to the START position is designed to bring a large quantity of primary air under the hearth of the firebox, to allow rapid
and effective ignition of the fire.
To achieve the best performance of the fireplace, after having started it and obtained a bed of uniform embers, set the air register in
position 4 - PERFORMANCE. Load every 41 minutes with 3 x 25 cm logs with an overall weight between 2.4 and 2.5 kg depending on what
model is chosen (see technical data table).
44

Advertisement

Table of Contents
loading

Table of Contents