FIRST START-UP ..........................25 5.4. FUEL LOADING ..........................26 5.5. COMBUSTION CONTROL .......................27 5.6. QUICK RESPONSE.........................27 5.7. 6. MAINTENANCE AND CLEANING ......................28 CLEANING UNDER THE USER'S RESPONSIBILITY ................28 6.1. Contents Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Page 3
Ash removal...........................28 6.1.2. ® Cleaning refractory walls (ALUTEC ) ..................28 6.1.3. CLEANING UNDER THE RESPONSIBILITY OF A SPECIALISED TECHNICIAN ........29 6.2. Cleaning the flue pipe ......................29 6.2.1. Contents Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
used additional explanations. NOTE: the “NOTE” provides the reader with additional information about the topic. These symbols indicate specific messages found in this manual Introduction Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
If this manual is destroyed request a copy from Tampering of any nature or replacement of spare your authorised retailer or from MCZ. parts with non-original parts may endanger the Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Please contact your retailer and/ or local importer in the event of product failure. Damage caused by transport and/ or handling are not covered by the guarantee. Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
230V 50 Hz electrical power supply offer a suitable smoke outlet system be fitted with external ventilation be fitted with an EC-compliant earthing system Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Avoid air inlets connected to thermal power plants, garages, kitchens or bathrooms. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
The flue pipe is vital for the correct functioning and during combustion positioned at the foot of safety of your closed fireplace. the external rising section. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
2 metres apart. In all cases the chimney must protrude from the ridge of the roof by at least 1 linear metre. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Dimensions of the Forma Wood 75 rh-lh (fig. shows lh version) 3.1. 705 porta door 455 porta door Ø99 Min.33 750 rivestimento Min. 33 cladding rivestimento cladding max.60 max. 60 Ø244 Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Dimensions of the Forma Wood 95 rh-lh (fig. shows lh version) 3.2. door door 455 porta 900 porta Ø99 Min.33 Min. 33 945 rivestimento cladding rivestimento cladding max.60 max. 60 1025 Ø244 Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Dimensions of the Forma Wood T95 3.3. 1067 1025 (porta) (door) porta (door) Ø99 MIN 33-MAX 60 1026 (rivestimento) rivestimento cladding (cladding) 514,5 514,5 Ø244 Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Over 5 m. 25x25 cm diameter 25 Notes Intermittent combustion appliance * These data may vary according to the type of fuel used Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
The closed fireplace must always be handled VERTICALLY and only using trolleys. Do not drag the unit as this may damage the support feet. Example of closed fireplace packaging Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Figure 1 – Counterweight locking screws Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
4.4. The FORMA WOOD closed fireplace can be positioned either in a corner or on a wall. MCZ cladding can be used to personalise the fireplace or built on site with materials able to withstand high temperatures. The closed fireplaces are self-bearing units that simplify installation and do not require any additional support.
WITH THE CLADDING. We recommend that you use the wheels (supplied) when moving the closed fireplace. Only the feet are needed to adjust the level. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
The filters or nets must be cleaned regularly to ensure that air can pass freely. Do not obstruct the air inlets for any reason if the closed fireplace or ventilation kit is operating. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
3. Marmo o altro materiale between the closed fireplace and the fire plane in order to fit the Figure 8 – Beam insulation insulation. (fig. 8) Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Grilles 1a and 1b are essential for discharge of heat that nestles inside the hood. It is essential to fit these grilles, notwithstanding the type of installation or cladding to be put in place. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
(if a COMFORT AIR FV kit is fitted) Start the fire on a moderate power level to check that there are no smoke/ soot leaks from the smoke connection. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Remove the stickers from the glass ceramic otherwise the high temperature may melt them and cause irreparable damage to the glass. MCZ will not guarantee the glass if you fail to do this. Open the front combustion air damper using the hook supplied.
3 chamber ( ). The running time of the appliance is approximately 45 minutes. On completion of combustion reload the appliance. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Nominal combustion has a duration of 50 mins. Therefore, to achieve the nominal hourly loading specified in the table in chapter 3 load the quantity shown in brackets in the table every 50 minutes. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
If you have time, remove the embers and ash using a metal container. Request urgent assistance from the competent authorities. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Detail of the handle for opening the tilting temperature in the combustion chamber rises (~ 400 °C). door A - CLOSED POSITION B - OPEN POSITION Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Page 29
Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
Page 30
MCZ GROUP S.p.A. Via La Croce 8 33074 Vigonovo di Fontanafredda (PN) – ITALY Telephone: +39 0434/599599 PBX Fax: +39 0434/599598 Internet: www.mcz.it e-mail: mcz@mcz.it 8901161300 Rev. 0 12/2011...
Need help?
Do you have a question about the FORMA WOOD 75 DX-SX and is the answer not in the manual?
Questions and answers