  • Page 1 INSTALLATION MANUAL 8901161300...
  • Page 2: Table Of Contents

    FIRST START-UP ..........................25 5.4. FUEL LOADING ..........................26 5.5. COMBUSTION CONTROL .......................27 5.6. QUICK RESPONSE.........................27 5.7. 6. MAINTENANCE AND CLEANING ......................28 CLEANING UNDER THE USER'S RESPONSIBILITY ................28 6.1. Contents Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 3 Ash removal...........................28 6.1.2. ® Cleaning refractory walls (ALUTEC ) ..................28 6.1.3. CLEANING UNDER THE RESPONSIBILITY OF A SPECIALISED TECHNICIAN ........29 6.2. Cleaning the flue pipe ......................29 6.2.1. Contents Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 4: Introduction

     used additional explanations.  NOTE: the “NOTE” provides the reader with additional information about the topic. These symbols indicate specific messages found in this manual Introduction Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 5: Warnings And Guarantee Terms

    If this manual is destroyed request a copy from  Tampering of any nature or replacement of spare your authorised retailer or from MCZ. parts with non-original parts may endanger the Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 6: Guarantee Terms

    Please contact your retailer and/ or local importer in the event of product failure. Damage caused by transport and/ or handling are not covered by the guarantee. Warnings and guarantee terms Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 7: Installation In Compliance With Uni 10683

    230V 50 Hz electrical power supply  offer a suitable smoke outlet system  be fitted with external ventilation  be fitted with an EC-compliant earthing system Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 8: Connecting The External Air Inlet

    Avoid air inlets connected to thermal power plants, garages, kitchens or bathrooms. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 9: Connecting The Flue Pipe

    The flue pipe is vital for the correct functioning and during combustion positioned at the foot of safety of your closed fireplace. the external rising section. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 10: Flue Pipe Examples

    Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 11: Chimney

    2 metres apart. In all cases the chimney must protrude from the ridge of the roof by at least 1 linear metre. Theoretical recommendations for installation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 12: Dimensions And Technical Specifications

    Dimensions of the Forma Wood 75 rh-lh (fig. shows lh version) 3.1. 705 porta door 455 porta door Ø99 Min.33 750 rivestimento Min. 33 cladding rivestimento cladding max.60 max. 60 Ø244 Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 13: Dimensions Of The Forma Wood 95 Rh-Lh (Fig. Shows Lh Version)

    Dimensions of the Forma Wood 95 rh-lh (fig. shows lh version) 3.2. door door 455 porta 900 porta Ø99 Min.33 Min. 33 945 rivestimento cladding rivestimento cladding max.60 max. 60 1025 Ø244 Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 14: Dimensions Of The Forma Wood T95

    Dimensions of the Forma Wood T95 3.3. 1067 1025 (porta) (door) porta (door) Ø99 MIN 33-MAX 60 1026 (rivestimento) rivestimento cladding (cladding) 514,5 514,5 Ø244 Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 15: Technical Specifications

    Over 5 m. 25x25 cm diameter 25 Notes Intermittent combustion appliance * These data may vary according to the type of fuel used Dimensions and technical specifications Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 16: Installation And Assembly

    The closed fireplace must always be handled VERTICALLY and only using trolleys. Do not drag the unit as this may damage the support feet. Example of closed fireplace packaging Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 17: Operating Mode Selection

    Figure 1 – Counterweight locking screws Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 18: Positioning

    4.4. The FORMA WOOD closed fireplace can be positioned either in a corner or on a wall. MCZ cladding can be used to personalise the fireplace or built on site with materials able to withstand high temperatures. The closed fireplaces are self-bearing units that simplify installation and do not require any additional support.
  • Page 19: Adjusting The Height And Level

    WITH THE CLADDING. We recommend that you use the wheels (supplied) when moving the closed fireplace. Only the feet are needed to adjust the level. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 20: External And Internal Air Inlets

    The filters or nets must be cleaned regularly to ensure that air can pass freely.  Do not obstruct the air inlets for any reason if the closed fireplace or ventilation kit is operating. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 21: Flue Pipe Connection

    3. Marmo o altro materiale between the closed fireplace and the fire plane in order to fit the Figure 8 – Beam insulation insulation. (fig. 8) Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 22: Closed Fireplace Insulation

    Grilles 1a and 1b are essential for discharge of heat that nestles inside the hood. It is essential to fit these grilles, notwithstanding the type of installation or cladding to be put in place. Installation and assembly Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 23: Operation

    (if a COMFORT AIR FV kit is fitted)  Start the fire on a moderate power level to check that there are no smoke/ soot leaks from the smoke connection. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 24: Choice Of Fuel

    Remove the stickers from the glass ceramic otherwise the high temperature may melt them and cause irreparable damage to the glass. MCZ will not guarantee the glass if you fail to do this.  Open the front combustion air damper using the hook supplied.
  • Page 25: First Start-Up

    3 chamber ( ). The running time of the appliance is approximately 45 minutes. On completion of combustion reload the appliance. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 26: Fuel Loading

    Nominal combustion has a duration of 50 mins. Therefore, to achieve the nominal hourly loading specified in the table in chapter 3 load the quantity shown in brackets in the table every 50 minutes. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 27: Combustion Control

     If you have time, remove the embers and ash using a metal container.  Request urgent assistance from the competent authorities. Operation Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 28: Maintenance And Cleaning

    Detail of the handle for opening the tilting temperature in the combustion chamber rises (~ 400 °C). door A - CLOSED POSITION B - OPEN POSITION Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 29 Maintenance and cleaning Technical dept. - All rights reserved by MCZ Group S.p.A. - Reproduction prohibited...
  • Page 30 MCZ GROUP S.p.A. Via La Croce 8 33074 Vigonovo di Fontanafredda (PN) – ITALY Telephone: +39 0434/599599 PBX Fax: +39 0434/599598 Internet: www.mcz.it e-mail: mcz@mcz.it 8901161300 Rev. 0 12/2011...