10-Operation - MCZ PLASMA 75Q RH/LH WOOD Instructions Manual

Closed fireplace
Table of Contents

Advertisement

10-OPERATION

WARNINGS BEFORE IGNITION
Make sure you have read and fully understood the contents of this instruction manual.
Remove all components that could burn from the firebox and door (instructions and various adhesive labels).
Remove the stickers from the ceramic glass otherwise the high temperature could melt them and cause irreparable damage to the glass.
The product can be positioned at in a corner or along a wall.
Avoid touching the product during the initial start-up, since the paint completes its drying process during this time
and hardens. It is good practice to guarantee effective ventilation in the room during the initial start-up, as the
product will emit some smoke and smell of paint, which is absolutely normal!
If necessary, touch up the paint with the spray can of the specific colour.
Do not stand close to the boiler and ventilate the room as described. The smoke and smell of paint will disappear after about an hour of
operation; however, they are not harmful in any case.
The product will be subject to expansion and contraction during the start-up and cooling stages, therefore slight
creaking noises may be heard.
This is absolutely normal as the structure is made of laminated steel and must not be considered a defect.
ONLY FOR FIRST TIME START-UP
It is extremely important to make sure the product is not immediately overheated and the temperature must be
increased gradually.
This will prevent damage to the welds and to the steel structure.
OPERATION TEST
ATTENTION!!
BEFORE CONTINUING WITH ANY CLADDING INSTALLATION OPERATION, PERFORM A GENERAL TEST ON THE CLOSED
FIREPLACE ACCORDING TO THE FOLLOWING:
• Raise and lower the door 7-8 times to make sure its slides easily and that the counterweights do not make any noise due to impact
against the structure.
• Make sure that cabling and control unit (if the COMFORT AIR VF kit is installed) are far away from the hot body of the closed fireplace.
• Test the ventilation kit at every speed and in every mode (when using the COMFORT AIR VF kit).
• Light the fire moderately, to ensure that the smoke fitting is tight / not leaking soot.
THE MANUFACTURER WILL NOT BE HELD LIABLE FOR DAMAGE TO THE CLADDING, IF THE ABOVE PREVENTIVE CHECKS
ARE NOT CARRIED OUT AND IT ENDS UP BEING NECESSARY TO DEMOLISH THE CLADDING TO MAKE REPAIRS OR
ADJUSTMENTS.
STEPS OF FIRST TRIAL IGNITION
• Make sure you have read and fully understood the contents of this instruction manual.
• Remove all components that could burn from the firebox of the closed fireplace and door (instructions and various adhesive labels).
• Remove the stickers from the ceramic glass otherwise the high temperature could melt them and cause irreparable damage to the
glass. If this is the case, the manufacturer will not guarantee the glass.
• Open the front combustion air grid register all the way using the cold handle.
• Put in wood in small pieces and thoroughly-dry (moisture of 15/20%).
40

Advertisement

Table of Contents
loading

Table of Contents