7-OPERATING MODE

OPERATING MODE SELECTION
IMPORTANT!
Before installation it is necessary to decide what system needs to be implemented.
The closed fireplace has the possibility of distributing hot air in NATURAL CONVECTION (COMFORT AIR VN) mode or FORCED
CONVECTION (COMFORT AIR VF) mode through the use of a forced ventilation kit.
IMPORTANT!
With both systems the installer is required to take down the knockout holes set up above the closed fireplace to facilitate thermal
exchange and air circulation.
The top knockout holes are round with Ø100 and Ø150 and at least two need to be opened and ducted ("C") for correct air diffusion.
To detach the knockout holes, use a drill with Ø4 mm bit (see image).
C
Natural convection (COMFORT AIR VN)
With natural ventilation, the air naturally enters the bottom of the closed fireplace.
Take off the diamond-shaped knockout hole from the back of the closed fireplace.
Forced convection (COMFORT AIR VF)
If you implement this system, purchase the Comfort Basic Air kit or the optional Comfort Air Slim kit and follow the instructions provided
with each kit.
EARTHING INSTRUCTIONS
If any electrical equipment is installed, the chimney must be safely connected to an earth contact, in accordance with regulations in force.
32