Battery Systems
3.2

Plug Connection Coding

The battery plugs of the machine, the
battery and the stationary charger unit
have to be coded according to the bat-
tery type and the nominal voltage with
coloured pins.
The charger unit's plugs are/will be
coded in the factory according to the
characteristic curve and changing the
characteristic curve (according to the
battery type) always requires modifica-
tion of the plug coding.
Plug case of charger unit:
- grey for wet batteries
- green for maintenance-free
Gel batteries
Machine plug case:
- yellow for both battery types
Battery socket case:
- grey for wet batteries
- green for maintenance-free
Gel batteries
Nominal voltage value for
Inscription for nomi-
plug printed on each side
nal voltage for sok-
of the hexagon (letters
kets accordingly
upside down)
Remove the coding pin by pressing the
ends together by means of pliers.
Press together for assembly
Insert pin such that the nominal volta-
ge inscription is visible through the ca-
se window. Socket and plug always
with the same nominal voltage!
The following three requirements have
to be met:
1) Voltage coding is the same for all
plugs and sockets
2) Coding pin colour in the machine =
yellow
3) Coding pin colour
Before first operation of the
machine, the batteries have
to be adequately charged by
an initial charging procedu-
re. Please observe the in-
structions of the charger
unit's operating manual.
Hako rejects any claim for
warranty on battery dama-
ges caused by unfulfilled in-
itial charging.