Table of Contents

Advertisement

rum Wa
2. Water Level Sensor
1) Spec. of Water Level Sensor
O/F: Forced drainage is
necessary as water
level is high. When
this level is reached,
water supply must be
stopped and drainage
must be forcefully
administered.
Model
Code
Classification
3614825220
Frequency
WD1132
DN-DD03,
Water level
DL-DW03
(mm)
2) Breakdown Analysis
Symptoms
Detailed Symptoms
Continuous
Water valve normal
water
supply
"E9"
Occurrence in water level
sensor
30kHz or higher
RESET :
1. Spin-drying begins
30sec after drainage
level reset is reached.
2. Heater operation level
O/F
Medium High Medium
22.60㎑
23.10㎑
23.20㎑
260±15
225±15
220±7
Cause
Defect in pressure sensor
Check for holes.
hose
Blocking of pressure sensor
Visual checking
hose
Connector loosened
Visually check connector
connection status.
Wiring short
Wiring short ->
conduction test
51
Low: Small load of laundry, therefore considered to be
water level of 'low'
Medium: Large load of laundry
Medium High: Water level for rinsing
Safety: Door open possible
Door opened only when water level is below
safety level
Low
Safety
Reset
24.00㎑
24.40㎑
24.70㎑
170±15
140±15
120±20
Diagnosis
Solution
Replace hose.
Remove foreign substances.
Administer re-insertion.
Initial(Defect) Inlet Angle
25.80㎑
90°
0
PCB Error
Mode
"E2"
"E2"
"E9"
"E9"