Daewoo DWD-WD125 Series Service Manual page 47

Table of Contents

Advertisement

3) H5 Error - Water temperature error in wool/ delicate course
① In case water temperature in wool/ delicate course is 45℃ or higher
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
① Within 15 minutes after heater operation begins;
In case standard temperature is of 42℃ or lower: If temperature does not increase by 2℃ or more In
case standard temperature is higher than 42℃: If temperature does not increase by1℃ or more
② If temperature falls below standard temperature by 2℃ or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
① In case washing heater temperature increases by 5℃ or more within 30 seconds when there is no
water in tank, etc.
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.
6-11. PFE (Pump Filter Error)
① Cycle is skipped to the next when the current r.p.m. is different from the target r.p.m by 70 during
interim spin-drying.
② Cycle is skilled to balance spin-drying when the current r.p.m is different from the target r.p.m by 70
during main spin-drying.
③ 'PFE' error is caused if main spin-drying skip of ② above occurs 10 times.
④ Error display is cleared when turning off/ on power.
46

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwd-wd135 seriesDwd-wd135 02 series

Table of Contents