rum Wa
5. MANUAL TEST MODE
- PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
: Press power button -> Press "SPIN" button 3 times with pressing "WASH" button -> "X X X" will be
shown on LED display-> Whenever pressing "Beeper" button 1 time, below process will be occurred.
- "X X X' : Program version display
Step
Display
1
L_C
2
run
3
b1
4
b2
5
b3
6
b4
7
b5
8
b6
9
b7
10
L
11
H
12
C
13
P
14
U
15
bb
16
dr
17
L_O
2) More details
- When turn on 'LOCK' signal, all process is conducting normaly.
- In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
Details
Door Lock Close
001
Running times count
0
HALL-SENSOR ERROR count
0
IPM-FAULT ERROR count
0
Over-load ERROR count
0
Motor align ERROR count
0
Rpm checking ERROR count
0
Overvoltage ERROR count
0
Low voltage ERROR count
No use
Hot Valve
Cold Valve
Pre Wash Valve
No use
Bleach Valve
Drain Pump
Lock Open