Daewoo DWD-WD125 Series Service Manual page 46

Table of Contents

Advertisement

rum Wa
6-9. Motor-related Error
1) E5 (DC-Link High Voltage) Error
① In case DC-link voltage to IPM increases to 450V or higher
② Motor operation is stopped and 'E5' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
2) E6 (EMG) Error
① In case current detected with EMG port is of 20A or higher
② Motor operation is stopped and 'E6' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
3) E7 (Direction) Error
① In case signal of Hall IC is different from the predicted signal according to direction of rotation
② Motor operation is stopped and 'E7' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
4) E8 (Initial Operation Fail) Error
① In case input signal of Hall IC is abnormal due to problems in motor connection, etc.
② Motor operation is stopped and 'E8' is shown in display window.
③ Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④ Error display is cleared when turning off/ on power.
6-10. Error in Temperature Sensor
1) H2 Error - Washing temperature sensor open/ short
① In case washing temperature sensor is defective or not connected
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.
2) H4 Error - Washing temperature sensor overheating
① In case temperature detected by washing temperature sensor is 95℃ or higher
② Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③ Error display is cleared when turning off/ on power.
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwd-wd135 seriesDwd-wd135 02 series