INSTALLER AND USER GUIDE FOR CROSS 90 DIRECT FLOW REVERSE OSMOSIS FILTER
9
3. FILTER INSTALLATION
1. Remove the reverse osmosis system from its packaging and check the equipment.
2. Shut off water supply in your kitchen or whole home and open water tap where you are about
to install the system (on your kitchen sink) for 1 minute to relieve pressure in the system, and
then close it.
3. Screw the feed water adapter with valve (4) into the cold water plumbing.
Connections size is selected to fit most common size ½ inch pipe. If your pipe is of another size,
prepare an appropriate adapter.
4. Unscrew the compression nut from the feed valve (4) and put it on the 3/8" white tube. Push
the white tube on the end of feed valve's fitting and screw on the compression nut. Connect the
free end of the 3/8" white tube with the quick connect fitting "Inlet" on the connection panel of
the rack. Insert the 3/8" quick coupling lock plate between the quick connect and the claw of the
water inlet pipe.
3/8" PE pipe in
proper length
3/8" quick coupling
lock plate
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2023