4. STEPS AFTER INSTALLATION
2. Measure TDS of supply water and TDS of purified water using a calibrated TDS meter.
3. Check the operation of the inlet solenoid valve. When closing the inlet valve (4), after 1.5
minutes (90 seconds), the low pressure switch is activated, the inlet valve is closed, and the
pump stops, the corresponding sound and light indication is activated (paragraph 6.6). When the
purified water faucet is turned off, the high pressure switch is activated, the inlet valve is closed
and the pump stops.
4. Check the unit for leaks.
5. Make record of commissioning in the maintenance log in paragraph 9 of this book.

5. USAGE

Domestic reverse osmosis system is designed for purification of cold water only.
To enjoy purified water of consistent quality, replacement filters should be replaced on time.
Delay in the replacement of cartridges can lead to deterioration or destruction of the membrane.
If the rate of filtration drops significantly and is not helped by replacing CF filter, you need to
replace reverse osmosis membrane.
If you do not plan to use the system for a long time, it is recommended to shut off the water
supply to the system and disconnect it from the power supply.

5.1 PARTS OF THE FILTER AND THEIR RECOMMENDED CHANGE OUT RATES

Replacement filter
CF Filter cartridge
RO Filter cartridge
CB Filter cartridge
Warning. The replacement cycle of each filter element suggested for this system is an average
value obtained according to the tap water conditions in different locations. If the local water
quality is below average, the actual filter element life will differ from the recommended filter
element life. If the filter element is prematurely clogged or defective, use the actual state of use
as a basis for replacing the filter element.
* The service life of the membranes and cartridges and the frequency of their replacement
depend on the quality of the incoming water.

5.2 THE PROCEDURE FOR CARTRIDGES REPLACING

Please replace the filter cartridge regularly according to the violet and red lights of the respective
replacement filter lifetime indicator (2-4) or faucet indicator (5).
The system has FAST&DRY filter replacement technology. The replacement process does not need
to cut off the water source.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2023
Replacement filter lifetime
/ Pure water treatment capacity
12 months / 4 000 L
24 months / 8 000 L
12 months / 4 000 L