INSTALLER AND USER GUIDE FOR CROSS 90 DIRECT FLOW REVERSE OSMOSIS FILTER
3. FILTER INSTALLATION
7. Installation of the faucet.
7.1. To install drinking water faucet (3) drill 15.5
mm (1/2") diameter hole for single way tap in a
convenient location at the sink or countertop.
Caution! metal shavings can damage your
unit, remove them carefully as soon as you
have drilled the hole. If the mounting surface
is ceramic or stone, you may need a special
carbide drill.
Mount the faucet on the sink or countertop as
shown in the figure. Upper gasket, gasket ring,
below gasket and installation knob on the faucet
shank must fix the faucet firmly on the surface.
7.2 Push the direct quick coupling as deeply as
possible to the bottom of the faucet's inlet water
threaded pipe and insert the fixing clip.
7.3 After the faucet is installed, insert the other
end of the 1/4" white tube of pure water pipe
connected to the rack into the quick connection
of the faucet and insert the fixing clip.
7.4 Take the faucet aviation connector and insert
it into the special connector on the connection
panel in the required direction, and fix it by
screwing it with a plastic ring.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2023
Data interface
Aviation interface
11
Faucet body
Upper gasket
Countertop
Gasket ring
Below gasket
Installation knob
Inlet water threaded pipe
Direct quick coupling
1/4" quick coupling
lock plate