Transition Networks SM12DP2XA-NA Install Manual

Transition Networks SM12DP2XA-NA Install Manual

Managed gigabit ethernet fiber switch

Advertisement

Quick Links

Transition Networks
SM12DP2XA Install Guide
SM12DP2XA
Managed Gigabit Ethernet Fiber Switch
(12) 100/1000Base-X SFP Slots + (2) 1G/10G SFP+ slots +
(2) 10/100/1000Base-T
Install Guide
33751 Rev. E
33751 Rev. E
https://www.transition.com
Page 1 of 32

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SM12DP2XA-NA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Transition Networks SM12DP2XA-NA

  • Page 1 Transition Networks SM12DP2XA Install Guide SM12DP2XA Managed Gigabit Ethernet Fiber Switch (12) 100/1000Base-X SFP Slots + (2) 1G/10G SFP+ slots + (2) 10/100/1000Base-T Install Guide 33751 Rev. E 33751 Rev. E https://www.transition.com Page 1 of 32...
  • Page 2 All trademarks and registered trademarks are the property of their respective owners. Copyright Notice/Restrictions Copyright© 2018-2020 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means (graphic, electronic or mechanical) without written permission from Transition Networks.
  • Page 3 Transition Networks SM12DP2XA Install Guide Cautions and Warnings Definitions Cautions indicate that there is the possibility of poor equipment performance or potential damage to the equipment. Warnings indicate that there is the possibility of injury to person. Cautions and Warnings appear here and may appear throughout this manual where appropriate. Failure to read and understand the information identified by this symbol could result in poor equipment performance, damage to the equipment, or injury to persons.
  • Page 4: Table Of Contents

    Transition Networks SM12DP2XA Install Guide Contents Introduction ................................. 6 Safety Statements ................................ 6 Features ..................................7 Benefits ..................................7 Specifications ................................8 Switch Architecture ..............................12 Network Management Options ..........................12 About This Manual ..............................12 Related Manuals ................................13 For More Information ..............................13 Front Panel .................................14...
  • Page 5 Transition Networks SM12DP2XA Install Guide Limited Lifetime Warranty .............................28 Contact Us ................................28 Technical Support...............................28 Compliance Information ............................29 FCC Regulations ..............................29 Canadian Regulations .............................29 Declaration of Conformity (DoC) ...........................29 High Risk Activities Disclaimer ..........................30 Electrical Safety Warnings ............................31 Electrical Safety ..............................31 Elektrische Sicherheit ............................31...
  • Page 6: Introduction

    Transition Networks SM12DP2XA Install Guide Introduction The SM12DP2XA Managed Gigabit Ethernet Fiber Switch is a next-generation Fiber Switch offering full suite of L2 features and additional 10GbE uplink connections. Advanced L3 features such as Static Route deliver better cost performance and lower total cost of ownership in Enterprise networks or backbone via fibber or copper connections.
  • Page 7: Features

    (includes 19” rack mount brackets) Optional Accessories (sold separately) 25130 Power Supply; Input: 88 -264VDC, 120-370VDC; Output: 48VDC, 39.8 Watts, -20°C to +70°C SFP Modules See Transition Networks SFP webpage SFP+ webpage. 33751 Rev. E https://www.transition.com Page 7 of 32...
  • Page 8: Specifications

    Transition Networks SM12DP2XA Install Guide Specifications Port Configuration Total Ports SFP (100M/1G) Uplinks (100M/1G/10G) Console 2 SFP+ (1G/10G) RJ45 2 RJ45 (100M/1G) Hardware Performance Forwarding Switching Capacity Backplane Mac Table Jumbo Frames Capacity 50.592 Mpps 68 Gbps 68 Gbps 32756...
  • Page 9 Transition Networks SM12DP2XA Install Guide Software Features Layer 2 Switching Standard Spanning Tree 802.1d ⚫ Spanning Tree Rapid Spanning Tree (RSTP) 802.1w ⚫ Protocol (STP) Multiple Spanning Tree (MSTP) 802.1s ⚫ Link Aggregation Control Protocol (LACP) IEEE 802.3ad Trunking Up to 8 groups ⚫...
  • Page 10 Transition Networks SM12DP2XA Install Guide Layer 3 Switching IPv4 Unicast: Static routing IPv4 Static Routing IPv6 Unicast: Static routing IPv6 Static Routing Security SSH secures Telnet traffic in or out of the switch, SSH v1 and v2 are supported Secure Shell (SSH)
  • Page 11 Transition Networks SM12DP2XA Install Guide Egress shaping and rate control ⚫ Per port ⚫ Management DHCP Server Support DHCP server to assign IP to DHCP clients Zero Touch Upgrade Upgrade single switch automatically when you get notification Remote Monitoring Embedded RMON agent supports RMON groups 1,2,3,9 (history, statistics, alarms,...
  • Page 12: Switch Architecture

    Transition Networks SM12DP2XA Install Guide Event/Error Log Syslog, SMTP (RFC821) Management Access SNMP, Web, Telnet, SSH Filtering CDP Aware Yes (Cisco Discovery Protocol) Edge Port BPDU Control whether a port explicitly configured as Edge will transmit and receive Filtering BPDUs.
  • Page 13: Related Manuals

    A printed Quick Start Guide is shipped with each unit. For Transition Networks Drivers, Firmware, etc. go to the Product Support webpage (logon required). For Transition Networks Manuals, Brochures, Data Sheets, etc. go to the Support Library (no logon required). For SFP information see Transition Networks webpage.
  • Page 14: Front Panel

    Transition Networks SM12DP2XA Install Guide Front Panel The switch front panel contains the power inputs, ports, LEDs and RESET button as shown and described below. 1000BASE-T Ports The switch contains 10/100/1000BASE-T RJ-45 ports. All RJ-45 ports support automatic MDI/MDI-X operation, auto-negotiation and IEEE 802.3x auto-negotiation of flow control, so the optimum data rate and transmission...
  • Page 15: Front Panel Leds

    Transition Networks SM12DP2XA Install Guide Front Panel LEDs The switch includes a LED panel for system and port indications that simplify installation and network troubleshooting. The LEDs are located on left side of the front panel for easy viewing. The LEDs are shown and described in the tables below.
  • Page 16: Rst (Reset) Button

    Transition Networks SM12DP2XA Install Guide RST (Reset) Button The front panel RST (Reset) button is recessed for access using a paper clip or something similar. Press and hold the RST (Reset) button for 2-7 seconds to reset or 7-12 seconds to restore to factory defaults;...
  • Page 17: Installation

    Transition Networks SM12DP2XA Install Guide Installation Site Selection The Switch can be mounted in a standard 19-inch equipment rack (Via Rack mount Kit). Be sure to follow the guidelines below when choosing a location. The site should: • Be at the center of all the devices you want to link and near a power outlet.
  • Page 18: Package Contents

    Transition Networks SM12DP2XA Install Guide Package Contents After unpacking the switch, please check the contents to be sure you have received all the components. Before beginning the installation, be sure you have all other necessary installation equipment. • One SM12DP2XA GbE Fiber Managed Switch •...
  • Page 19: Desktop Or Shelf Mounting

    Transition Networks SM12DP2XA Install Guide Desktop or Shelf Mounting 1. Attach the four adhesive rubber feet to the bottom of the first switch. 2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow.
  • Page 20: Ethernet Cabling

    Transition Networks SM12DP2XA Install Guide Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for your operating environment. Check the following criteria against the current installation of your network: •...
  • Page 21: Installing An Optional Sfp Transceiver

    The mini-GBIC ports operate only at full duplex. Half duplex operation is not supported. • Ensure the network cable is NOT connected when you install or remove a mini-GBIC. NOTE: SFP transceivers are not provided in the switch package. See the Transition Networks Optical Devices webpage.
  • Page 22: To Install An Sfp Transceiver

    Transition Networks SM12DP2XA Install Guide To Install an SFP transceiver 1. Consider network and cabling requirements to select an appropriate SFP transceiver type. 2. Remove and keep the LC port’s rubber plug. When not connected to a fiber cable, the rubber plug should be replaced to protect the optics.
  • Page 23: Connecting To Power

    Transition Networks SM12DP2XA Install Guide Connecting to Power The AC/DC Dual Power Supply can provide power failover when power supplies are connected to different circuits to help reduce network operating risk. With fiber and copper cabling completed, and AC and/or DC power applied, the port LEDs light, the SYS LED flashes, the AC and/or DC LEDs light and the SYS LED goes from flashing to steadily lit.
  • Page 24: Initial Switch Configuration

    Transition Networks SM12DP2XA Install Guide Initial Switch Configuration Initial switch configuration can be via CLI or web browser. The factory defaults are IP Address: 192.168.1.77, User Name: admin, and Password: admin. CLI Configuration The command-line interface (CLI) is a text-based interface that you can access the CLI through either a direct serial connection to the device or a Telnet session.
  • Page 25: Troubleshooting, Warranty, Support And Compliance

    Verify that the proper cable type is used and its length does not exceed specified limits. Check the adapter on the attached device and cable connections for possible defects. Replace the defective adapter or cable if necessary. 11. Contact Transition Networks Tech Support for assistance. See Contact Us below.
  • Page 26: Led Troubleshooting

    Transition Networks SM12DP2XA Install Guide LED Troubleshooting The LED behavior is summarized below. Color Function Lit Green when Power A on Switch is Ready. POWER/Alarm Green/Red Lit Red when FAN, Temperature or Voltage Detected Fault Global Blinks when POST Running...
  • Page 27: Recording Device And System Information

    After performing the troubleshooting procedures, and before calling or emailing Technical Support, please record as much information as possible in order to help the Transition Networks Tech Support Specialist. 1. Select the SM12DP2XA Configuration > System > Information menu path. From the CLI, use the show commands needed to gather the information below or as requested by the TN Support Specialist.
  • Page 28 Transition Networks SM12DP2XA Install Guide Limited Lifetime Warranty To return a defective product for warranty coverage, contact Transition Networks’ technical support department for a return authorization number. Contact Us Technical Support Technical support is available 24-hours a day US and Canada: 1-800-260-1312...
  • Page 29 Transition Networks SM12DP2XA Install Guide Compliance Information FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 30 Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems ("High Risk Activities"). Transition Networks and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities.
  • Page 31 Transition Networks SM12DP2XA Install Guide Electrical Safety Warnings Electrical Safety IMPORTANT: This equipment must be installed in accordance with safety precautions. Elektrische Sicherheit WICHTIG: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen erforderlich. Elektrisk sikkerhed VIGTIGT: Dette udstyr skal installeres i overensstemmelse med sikkerhedsadvarslerne.
  • Page 32 Minnetonka, MN 55343, U.S.A. tel: +1.952.941.7600 | toll free: 1.800.526.9267 | fax: 952.941.2322 sales@transition.com techsupport@transition.com customerservice@transition.com Copyright © 2018-2020 Transition Networks. All rights reserved. Printed in the U.S.A. SM12DP2XA Install Guide, 33751 Rev. E 33751 Rev. E https://www.transition.com Page 32 of 32...