Incline Home Switch; Replacement - Life Fitness Aspire ASPT-SL Service Manual

Table of Contents

Advertisement

Incline Home Switch Replacement
Tools Required:
• Phillips screwdriver
• Torque wrench
Time:
20 minutes
Disconnect Power Source
Unplug power cord from power outlet.
WARNING: Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Remove Motor Cover
1. Remove screw securing motor cover to front shroud using a Phillips screwdriver.
2. Remove motor cover by lifting vertically. It is held in place with Tinnerman clips on the motor side shrouds and
front cover.
Item
1
Description
Motor Cover
Item
1
Page 46 of 98
Description
Screw
Qty.
1
Qty.
1