CLEARPOINT
®
water separator
9.4 Replace the float drain
For float drain replacement to be carried out, the following prerequisites must be fulfilled and the preparatory tasks
must have been completed.
Tools
•
Screwdriver - cross-head
size 2.5 mm
1.
Open the bypass pipe if available
Illustration
1.
2.
Automatic discharge
32 | 56
Prerequisites
Material
•
New float drain with adapter
enclosed
Preparation of installation
Description
1.
1. Close the shut-off valves upstream and downstream of
2. Set the knurled screw on the float drain anti-clockwise
Mechanically open
Installation and operation manual
Protective equipment
•
Protective gloves (fluid-
resistant)
•
Safety goggles with side shields
•
Hearing protection
•
Respiratory protection,
protection class FFP 3
•
Safety footwear
the separator or the respective system section
(left-hand thread) from >>Automatic discharge<< to
>>Mechanical open<<