Reporting interval of battery level to network server. Default: 1080min,
Reporting Interval
Range: 1-1080 mins
Enable or disable the light indicating in chapter 2.4.
LED Indicator
Note:
The buzzer will be triggering together with indicator if the device is
Buzzer
registered to network.
Enable or disable double press mode.
Double Press
Note:
D2D will also be hidden.
Change Password Change the password for ToolBox App to write this device.

3.5 Advantech D2D Settings

Advantech D2D protocol is developed by Advantech and used for setting up transmission
among Advantech devices without gateway. When the Advantech D2D setting is enabled,
LEO-S595-WBG0 can work as a Advantech D2D controller to send control commands to
trigger Advantech D2D agent devices.
1. Configure RX2 datarate and RX2 frequency in LoRaWAN
change the default value if there are many LoRaWAN
2. Enable Advantech D2D feature.
3. Define a unique Advantech D2D key which is the same as Advantech D2D agent devices,
then select the frequency and spreading factor. (Default Advantech D2D Key:
5572404C696E6B4C6F52613230313823)
4. Enable one of LEO-S595-WBG0 button mode and configure a 2-byte hexadecimal
command (This command is pre-defined in Advantech D2D agent device). When you press as
this button mode, LEO-S595-WBG0 will send the control command to corresponding
Advantech D2D agent devices.
Note:
When LoRa Uplink feature is enabled, a LoRaWAN
of button status will be sent to gateway after the Advantech D2D control command packet.
www.advantech.com
The indicator of reset button is not allowed to disable.
If double press is disabled, double press settings under Advantech
®
settings, it is suggested to
®
devices around.
®
uplink packet that contains the info