Channel
ff

5.3 Downlink Commands

LEO-S595-WBG0 supports downlink commands to configure the device. The application port
is 85 by default.
Channe
l
ff
74 (Set Double Press Mode)
Examples:
1. Set reporting interval as 20 minutes.
Channel
ff
2. Reboot the device.
Channel
ff
3. Disable double press mode.
Channel
ff
www.advantech.com
ff 2e 01
Type
2e(Button Message)
Type
03 (Set Reporting Interval)
10 (Reboot)
2f (Set LED Indicator)
3e (Set Buzzer)
ff03b004
Type
03 (Set Reporting
Interval)
ff10ff
Type
10 (Reboot)
ff7400
Type
74 (Set Double Press)
-END-
Value
01 => short press
Description
2 Bytes, unit: s
ff (Reserved)
00: Disable
01: Enable
00: Disable
01: Enable
00: Disable
01: Enable
Value
b0 04 => 04 b0 = 1200s
= 20 minutes
Value
ff (Reserved)
Value
00 => Disable
16