Advantech LEO-S595-WBG0 User Manual

Advantech LEO-S595-WBG0 User Manual

Smart button featuring lorawan

Advertisement

Quick Links

Smart Button
®
Featuring LoRaWAN
LEO-S595-WBG0 / LEO-S595-WBC0
User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEO-S595-WBG0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Advantech LEO-S595-WBG0

  • Page 1 Smart Button ® Featuring LoRaWAN LEO-S595-WBG0 / LEO-S595-WBC0 User Guide...
  • Page 2 Safety Precautions Advantech will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. ❖ The device must not be modified in any way. ❖ In order to protect the security of the device, please change device the password when first configuration.
  • Page 3: Table Of Contents

    3.1 Button Mode ........................6 3.2 NFC Configuration ......................6 3.3 LoRaWAN Settings ......................7 3.4 General Settings ....................... 10 3.5 Advantech D2D Settings ....................11 3.6 Maintenance ........................12 3.6.1 Upgrade ........................12 3.6.2 Backup ........................12 3.6.3 Reset to Factory Default ..................13 4.
  • Page 4: Product Introduction

    LEO-S595-WBG0 is a LoRaWAN based smart button for wireless controls, triggers and alarms. LEO-S595-WBG0 supports multiple press actions, all of which can be defined by the user to control devices or trigger scenes. Compact and battery-powered, LEO-S595-WBG0 is easy to install everywhere. LEO-S595-WBG0 can be widely used in smart homes, smart offices, hotels, schools, etc.
  • Page 5: Hardware Overview

    2.3 Dimensions (mm) 2.4 LED Patterns LEO-S595-WBG0 equips with a LED indicator to indicate the network status and reset button features. Besides, when button is pressed, the indicator will light up at the same time. Red indicator means network is unregistered, while green indicator means device has registered on network.
  • Page 6: Operation Guide

    Press and hold the reset button for more than 10s Quickly blinks Default 3. Operation Guide 3.1 Button Mode LEO-S595-WBG0 provides 3 kinds of pressing actions allowing users to define different alarms. Please refer to chapter 5.1 for detailed message of every action. Mode Action Mode 1 Short press the button (≤3 seconds).
  • Page 7: Lorawan Settings

    2) If the smartphone fails to read/write configurations via NFC, move the phone away and back to try again. 3) LEO-S595-WBG0 can also be configured by ToolBox software via dedicated NFC reader provided by Advantech, you can also configure it via TTL interface inside the device.
  • Page 8 V1.0.2, V1.0.3, V1.1 are available. Work Mode It’s fixed as Class A. RX2 Data Rate RX2 data rate to receive downlinks or send Advantech D2D commands. RX2 Frequency RX2 frequency to receive downlinks or send Advantech D2D commands. Unit: www.advantech.com...
  • Page 9 Go to Setting > LoRaWAN Settings of ToolBox App to select supported frequency and select ® channels to send uplinks. Make sure the channels match the LoRaWAN gateway. If device frequency is one of CN470/AU915/US915, you can enter the index of the channel www.advantech.com...
  • Page 10: General Settings

    Null: Indicates that all channels are disabled Note: For -868M model, default frequency is EU868; For -915M model, default frequency is AU915. 3.4 General Settings Go to Device > Setting > General Settings of ToolBox App to change the reporting interval, etc. Parameters Description www.advantech.com...
  • Page 11: Advantech D2D Settings

    LoRaWAN devices around. 2. Enable Advantech D2D feature. 3. Define a unique Advantech D2D key which is the same as Advantech D2D agent devices, then select the frequency and spreading factor. (Default Advantech D2D Key: 5572404C696E6B4C6F52613230313823) 4.
  • Page 12: Maintenance

    1) Operation on ToolBox is not supported during upgrade. 2) Only Android version ToolBox supports the upgrade feature. 3.6.2 Backup LEO-S595-WBG0 supports configuration backup for easy and quick device configuration in ® bulk. Backup is allowed only for devices with the same model and LoRaWAN frequency www.advantech.com...
  • Page 13: Reset To Factory Default

    Hold on the reset button for more than 10s. After reset complete, the indicator will blink in green twice and device will reboot. Via ToolBox App: Go to Device > Maintenance to tap Reset, then attach smartphone with NFC area to device to complete reset. www.advantech.com...
  • Page 14: Installation

    All data are based on the following format(HEX), the Data field should follow little-endian: Channel1 Type1 Data1 Channel2 Type2 Data2 Channel 3 1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte 5.1 Basic Information LEO-S595-WBG0 reports basic information of button whenever joining the network. www.advantech.com...
  • Page 15: Button Message

    (Class A) version) 5.2 Button Message LEO-S595-WBG0 reports battery level according to reporting interval (1080 mins by default) and button message when button is pressed. Besides, when battery level is lower than 10%, it will upload battery packet once. Channel...
  • Page 16: Downlink Commands

    2e 01 Channel Type Value 2e(Button Message) 01 => short press 5.3 Downlink Commands LEO-S595-WBG0 supports downlink commands to configure the device. The application port is 85 by default. Channe Type Description 03 (Set Reporting Interval) 2 Bytes, unit: s...