2.4.4 "BOOST", "SMART" and "SILENCE" mode
The PX50 heat pump can adapt its power to suit the pool temperature and weather conditions. In doing so, it obtains
maximal energy efficiency at a very low noise level.
HIGH
MID
LOW
Operating
The heat pump operates at full
principle
Heating: when commissioning
When to use
Cooling: hot zones, heat waves,
* The compressor speed directly affects the appliance's power output.
BOOST ,
• Press
Information: "SMART" mode
• When the heat pump is operating at full power in "SMART" mode, the "SMART" indicator light is lit and
the "BOOST" indicator light flashes.
Information: "SILENCE" mode
• When the heat pump is operating at medium power in "SILENCE" mode, the "SILENCE" indicator light is
lit and the "SMART" indicator light flashes.
2.4.4 Configuring the "TIMER"
• Press
then
"TIMER".
Settings
P2
P5
P6
18
Silence
"BOOST" mode
power.
the pool.
sheltered pools, etc.
SMART
or SILENCE the indicator above the selected mode is lit.
to view the "timer activation" ("P2"), "on time" ("P5") and "off time" ("P6") settings for the
Meaning
Timer activation
On time
Off time
Boost
"SMART" mode
The heat pump operates
intelligently, at medium to high
speeds.
Adapts the power automatically to requirements.
To maintain the temperature
When you don't want to handle
the appliance
Amplitude
Default setting
0 - 1
HH:MM
00:00
HH:MM
00:00
Power
"SILENCE" mode
The heat pump operates at low
power for lower consumption
and less noise.
Low heating requirements and
silent operation desired
Comments
0 = timer disabled
0
1 = timer enabled
0-23:0-59