Z950
Operating temperatures
Defrosting by cycle inversion
Voltage
Admissible variation in voltage
Pollution class
Pollution degree
Overvoltage category
Protection fuse (F, quick)
Protection rating
Refrigerant gas R410-A
Minimum cable section*
Proof pressure
Service pressure
Maximum inlet pressure
Head loss
Recommended water flow rate
Acoustic power
Acoustic pressure at 10 m
Net weight
Gross weight
PERFORMANCE: 15 °C air / 26 °C water / Humidity : 70%
Power consumed
Power output
Average COP
PERFORMANCE: 28 °C air / 28 °C water / Humidity : 80%
Power consumed
Power output
Average COP
* Values provided for information purposes for a maximum length of 20 metres (calculation base: NFC15-100), must be checked and adapted to the
installation conditions and standards of the installation country.
** In accordance with the standards UNE-EN 12102 / ISO 3744:2010
TD35
air
water
kg
6
mm²
4
bar
bar
bar
KPa
15
m³/h
13
db(A)**
83
db(A)**
52
kg
185
kg
195
kW
6.20
kW
30.53
4.92
kW
6.93
kW
39.48
5.69
TD45
TD60
-12 to 38 °C
10 to 40 °C
Air T°C < 10 °C
400V/3/50 Hz
± 10 % (during operation)
I
2
II
10 A / 250 V
IP44
7.5
9
6
10
3
1.5
3.5
50
41.6
20
30
83
90
52
58
210
287
220
310
8.10
11.50
39.70
56.80
4.90
4.94
8.53
12.25
47.94
68.1
5.62
5.54
TD90
TD120
EN
2 x 9
2 x 11
16
25
52
74
42
60
90
90
58
58
447
500
475
545
16.80
23.90
80.20
110.50
4.77
4.62
17.6
24.97
98.1
133.1
5.56
5.32