Inogen Rove 6 User Manual
Hide thumbs Also See for Rove 6:

Advertisement

Inogen Rove 6
PORTABLE OXYGEN
CONCENTRATOR
System Catalog: IS-501
Concentrator Catalog: IO-501
USER
MANUAL
ENGLISH
Caution: USA Federal law restricts this
device to sale by or on the order of a
physician. May also be applicable in
other countries.
96-13115-00-01 B | Page 1 of 40

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rove 6 and is the answer not in the manual?

Questions and answers

Don Enns
June 5, 2025

how to turn off rove 6 battery operated using inogen app?

Subscribe to Our Youtube Channel

Summary of Contents for Inogen Rove 6

  • Page 1 Inogen Rove 6 PORTABLE OXYGEN CONCENTRATOR System Catalog: IS-501 Concentrator Catalog: IO-501 USER MANUAL ENGLISH Caution: USA Federal law restricts this device to sale by or on the order of a physician. May also be applicable in other countries. 96-13115-00-01 B | Page 1 of 40...
  • Page 2: Glossary Of Symbols

    (operating) Contents Electrical Safety Agency Certificate Authorized Representative for Switzerland CH REP For icon displayed on the user interface panel refer Product Catalog Description to section 7. ©2023 Inogen, Inc. All rights reserved. Page 2 of 40 96-13115-00-01 B...
  • Page 3: Table Of Contents

    1. PRODUCT CONTENT AND QUICK START GUIDE ............4 2. INTRODUCTION ......................... 5 3. INDICATIONS AND INTENDED USE ................. 5 4. SAFETY INSTRUCTIONS ....................6 5. INOGEN ROVE 6 DESCRIPTION..................9 6. GENERAL INSTRUCTIONS ....................10 7. ALARM INDICATORS & DEVICE ICON GLOSSARY ............19 8. TROUBLESHOOTING....................... 25 9.
  • Page 4: Product Content And Quick Start Guide

    IMPORTANT: The Quick Start Guide is for reference ONLY. It is imperative to read the complete user manual before use. Before getting started, confirm that your Inogen Rove 6 Portable Oxygen Concentrator system includes the following components: 1x DC Power Cable...
  • Page 5: Introduction

    This device is to be used as an oxygen supplement and is not intended to be life sustaining or life supporting. 3.2 INDICATIONS FOR USE AND CLINICAL BENEFIT The Inogen Rove 6 is used on a prescriptive basis by patients requiring supplemental oxygen to increase blood oxygen saturation. 3.3 CONTRAINDICATIONS This device is to be used as an oxygen supplement and is NOT INTENDED to be life sustaining or life supporting.
  • Page 6: Safety Instructions

    Use only water-based lotions or salves that are oxygen-compatible during setup or use during • The Rove 6 is MR Unsafe. Do not expose to MRI oxygen therapy. equipment or other devices that generate strong magnetic fields (for example, x-ray, CT scan, or •...
  • Page 7 5 – 40°C (41 – 104° F) or a relative humidity above instructions for use are at the sole responsibility 95% is expected to adversely affect the flowrate for the patient. Inogen assumes no liability for and the percentage of oxygen and consequently use of parts and accessories not mentioned in the quality of the oxygen therapy.
  • Page 8 Doing so will minimize the risk of interrupting operation and will keep alarms functioning. ©2023 Inogen, Inc. All rights reserved. Page 8 of 40 96-13115-00-01 B...
  • Page 9: Inogen Rove 6 Description

    AC power supply, DC power cable, rechargeable battery pack and carry bag. This section is intended to help familiarize you with the device’s components and interface. Do not perform any actions on or with your POC until after reading Section 6, General Instructions Inogen Rove 6. Flow setting control buttons...
  • Page 10: General Instructions

    DO NOT USE near pollutants, smoke, fumes, flammable anesthetics, cleaning agents or chemical vapors. DO NOT USE in environments where your concentrator could become submerged in water. DO NOT USE near oil, grease or petroleum-based products. ©2023 Inogen, Inc. All rights reserved. Page 10 of 40 96-13115-00-01 B...
  • Page 11 DO NOT lubricate fittings, connections, tubing, or other accessories of your concentrator. • Connect the nasal cannula tubing by inserting it onto the metal cannula barb on the top of the device. ©2023 Inogen, Inc. All rights reserved. Page 11 of 40 96-13115-00-01 B...
  • Page 12 • Press and hold the Power button until you hear a single short beep. • The display will light up and the Inogen logo will appear on the display. IMPORTANT: If the display light immediately turns off after the Inogen logo appears, you have not held the power button long enough.
  • Page 13 Cart • The Cart has wheels and a telescoping handle to provide easy transport of the Inogen Rove 6. The Inogen Rove 6 can be operated using battery power during transport. Place the carry bag over the cart handle. Make sure the cart handle is inserted through the sleeve opening in the back of the carry bag.
  • Page 14 Not all accessories are included with your system and can be purchased separately. The following optional accessories and replacement parts can be purchased from your equipment provider or the manufacturer Inogen, at Inogen.com or by calling 1-877-466-4364. Description...
  • Page 15 Leaving your device plugged in past the full charge time will not harm the device or the battery. If using multiple batteries, make sure that each battery is labeled (1, 2, 3 or A, B, C, etc.) and rotate on a regular basis. ©2023 Inogen, Inc. All rights reserved. Page 15 of 40 96-13115-00-01 B...
  • Page 16 6.11 AC POWER SUPPLY (BA-502/BA-501) The Inogen Rove 6 POC includes an AC power supply that connects to the device and an AC power cable to connect to the power supply and corresponding AC outlet. The AC power supply will automatically adapt to input voltages from 100V-240V (50-60Hz).
  • Page 17 (if you have one) with you. It is advisable to use external power (i.e., plugged into a wall) whenever it is available to keep the battery fully charged. ©2023 Inogen, Inc. All rights reserved. Page 17 of 40 96-13115-00-01 B...
  • Page 18 Important: The alarm system is tested during the startup sequence. You should see all alarm lights briefly turn on and the audible alarm indicator chirp. If alarms are suspected of misoperating, contact your distributor for verification that alarms are working correctly. ©2023 Inogen, Inc. All rights reserved. Page 18 of 40 96-13115-00-01 B...
  • Page 19: Alarm Indicators & Device Icon Glossary

    Buzzer level 2 Buzzer level 4 7.3 BLUETOOTH ICONS (FOR MODELS WITH BLUETOOTH) Bluetooth turned off. Bluetooth turned on. Pairing with Inogen Connect application. Concentrator unpaired from mobile device. ©2023 Inogen, Inc. All rights reserved. Page 19 of 40 96-13115-00-01 B...
  • Page 20 Data log transfer in progress or update in progress (app only): This icon is displayed during all data log transfers and software updates initiated through the Inogen Connect App. Data log transfer success (app only): This icon is displayed after data log transfers have been successfully completed through the Inogen Connect App.
  • Page 21 To access the alarm log, ensure the concentrator is plugged and turned off. Then hold the plus (+) button for 5 seconds. Alternatively, the alarm log can be found in the Advanced Tab of the Inogen Connect App under Error Recall.
  • Page 22 What To Do Battery low, attach plug: Attach an external power supply turn Battery power is low with less off and insert a fully charged battery. than 10 minutes remaining. ©2023 Inogen, Inc. All rights reserved. Page 22 of 40 96-13115-00-01 B...
  • Page 23 Oxygen error: Oxygen output If condition persists, switch to your concentration has been below backup oxygen source and contact 50% for 10 minutes. your equipment provider to arrange for service. ©2023 Inogen, Inc. All rights reserved. Page 23 of 40 96-13115-00-01 B...
  • Page 24 System Error: The concentrator Switch to backup oxygen source will shut down and stop and contact your equipment producing oxygen. provider. ©2023 Inogen, Inc. All rights reserved. Page 24 of 40 96-13115-00-01 B...
  • Page 25: Troubleshooting

    9. CONNECTIVITY OPTIONS The Inogen Connect App pairs your portable oxygen concentrator to your mobile device or tablet using Bluetooth technology. It is not available in every country – contact your equipment provider for more information.
  • Page 26 9.1 PAIRING YOUR DEVICE WITH THE MOBILE APPLICATION 1. Download the Inogen Connect App • On your smart phone or tablet, search for ‘Inogen Connect’ in the App Store (Apple) or Google Play (Android). 2. Put the device in standby mode •...
  • Page 27: Cleaning, Care And Maintenance

    • Turn off the concentrator’s Bluetooth when not paired with the Inogen Connect App The Inogen Connect App is compatible with the following devices: iPhone 6 and later; iPad Air, iPad Air 2, iOS 9 and later, Samsung S5 and later; Nexus 5, Nexus 6, Nexus 9, Android 6 and later.
  • Page 28 • Housing - the housing should be fully seated and secure with no cracking or other visible damage. • Particle filters - these should be in place and clear of debris, dust or other obstructions. Replacement parts can be purchased from your equipment provider or the manufacturer Inogen, at Inogen.com or by calling 1-877-466-4364.
  • Page 29 2. Remove the particle filters from both intake ends of the device. 3. Clean the particle filters with a mild liquid detergent and water, rinse in water and dry fully before reuse. To purchase additional particle filters, contact your equipment provider or the manufacturer Inogen, at Inogen.com or by calling 1-877-466-4364.
  • Page 30 Press and hold the power button to turn on the device. 16. Resetting the columns through Inogen Connect App a. Open the Inogen Connect App on your mobile device or tablet. b. Navigate to the Advanced screen. c. Click on Additional Information.
  • Page 31: Device Repair And Disposal

    11. DEVICE REPAIR & DISPOSAL 11.1 REPAIR Do not attempt to repair the device unless otherwise specified in these instructions for use. Contact your equipment provider or Inogen for assistance. ©2023 Inogen, Inc. All rights reserved. Page 31 of 40...
  • Page 32: Technical And Product Specifications

    Representative for disposal instructions. The battery contains lithium-ion cells and should be recycled. The battery must not be incinerated. 12. TECHNICAL AND PRODUCT SPECIFICATIONS 12.1 SPECIFICATIONS Inogen Rove 6 Portable Oxygen Concentrator (Model # IO-501) Mains Isolation Remove both the DC input cable from device as well as the battery pack.
  • Page 33 Inogen Rove 6 Portable Oxygen Concentrator (Model # IO-501) Shipping and storage temperature -13 to 158˚F (-25 to 70˚C) Shipping and storage humidity Up to 90%, non-condensing Store in a dry environment. Measurement uncertainties: Pulse volumes: ± 15% of rated volume Pressure: ±...
  • Page 34 The Concentrator is intended for use in the electromagnetic environment of home, institution, vehicle, and other transport modalities. The user of the concentrator should make sure it is used in such an environment. During the immunity testing specified below the Rove 6 will continue to deliver oxygen within specification.
  • Page 35 0 °, 45 °, 90 °, 135 °, home, institution, vehicle and other transportation voltage variations 180 °, 225 °, 270 °, and and mobile environments. If the user of the Rove 6 on power supply 315 °. requires continued operation during power mains...
  • Page 36: Wireless Communication, Specifications And Compliance

    º Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. º Consult the dealer or an experienced radio/TV technician for help. ©2023 Inogen, Inc. All rights reserved. Page 36 of 40 96-13115-00-01 B...
  • Page 37: Limited Warranty Statement

    電機設備之干擾。 14. LIMITED WARRANTY STATEMENT The device comes with a 3 year warranty (refer to customer invoice). The Product is warranted by Inogen to be free from defects in materials and workmanship under normal use and service and when correctly maintained for the time set out in the warranty statement provided with the Product, which period shall begin on the Original Shipment Date.
  • Page 38: Trademarks And Disclaimer

    Healthcare Professionals: To report an adverse experience with a specific Inogen product, please call the Inogen Customer Care Center at 1-877-466-4364. You may also report an adverse event directly to the U.S. Food and Drug Administration (FDA) by calling 1-800-FDA-1088 or visiting http://www.fda.gov/Safety/MedWatch.
  • Page 39 ©2023 Inogen, Inc. All rights reserved. Page 39 of 40 96-13115-00-01 B...
  • Page 40 Inogen, Inc. 301 Coromar Drive Goleta, CA 93117, USA Toll Free: 877-466-4362 +1-805-562-0515 (Outside the USA) E-mail: info@inogen.net inogen.com USA United States JULY/2023 ©2023 Inogen, Inc. All rights reserved. Page 40 of 40 96-13115-00-01 B...

This manual is also suitable for:

Is-501Io-501

Table of Contents

Save PDF