Control Panel Status Indicators And Error Messages - Porsche Mobile Charger Driver Manual

Hide thumbs Also See for Mobile Charger:
Table of Contents

Advertisement

Control panel status indicators and error messages

Pilot lights
ON/OFF lights up green.
Power supply/household connection is off.
Vehicle is off.
Control panel is off.
Reset is off.
ON/OFF pulses green.
Power supply/household connection is off.
Vehicle is off.
Control panel is off.
Reset is off.
ON/OFF pulses green.
Mains supply/household connection lights up
yellow.
Vehicle is off.
Control panel is off.
Reset is off.
ON/OFF pulses green.
Mains supply/household connection lights up
yellow.
Vehicle lights up yellow.
Control panel is off.
Reset is off.
Meaning
The charger is ready but not charging.
The vehicle is charging with protective con-
ductor monitoring activated.
The power plug is overheated.
Possible cause: multiphase electrical socket
connected only as single phase.
Charging process is at reduced power.
The vehicle is being charged with protective
conductor monitoring deactivated.
Control panel status indicators and error messages
Remedy
e
Start charging process.
g Refer to chapter "Starting charging" on page 13.
The fault is automatically reset once the power plug has
cooled.
Until it has cooled, charging is only at reduced power.
e
If the fault persists, have the power supply/household
connection checked by a qualified electrician.
The vehicle should ideally be charged with protective conduc-
tor monitoring activated.
g Refer to chapter "Activating protective conductor monitor-
ing" on page 14.
15