Control Unit Status Indicators And Error Messages - Porsche 7PP.971.675.J Manual

Mobile charger
Hide thumbs Also See for 7PP.971.675.J:
Table of Contents

Advertisement

Control unit status indicators and error messages

Indicator lights
ON/OFF lights up green.
Power supply/domestic connection is off.
Vehicle is off.
Control unit is off.
Reset is off.
ON/OFF pulses green.
Power supply/domestic connection is off.
Vehicle is off.
Control unit is off.
Reset is off.
ON/OFF pulses green.
Power supply/domestic connection lights up
yellow.
Vehicle is off.
Control unit is off.
Reset is off.
ON/OFF pulses green.
Power supply/domestic connection lights up
yellow.
Vehicle lights up yellow.
Control unit is off.
Reset is off.
46
Meaning
The charger is ready for charging, but no
charging takes place.
The vehicle is charged with protective con-
ductor monitoring activated.
The power plug is overheated.
Possible fault cause: Multiphase socket con-
nected only as single phase.
Charging is performed at a reduced rate.
The vehicle is being charged with protective
conductor monitoring deactivated.
Remedy
e
Start charging process.
g Refer to chapter "Starting charging" on page 45.
The fault is automatically reset once the power plug has
cooled down.
Until it has cooled down, charging takes place only at a re-
duced rate.
e
If the fault persists, have the power supply/domestic
connection checked by a qualified electrician.
The vehicle should ideally be charged with protective conduc-
tor monitoring activated.
g Refer to chapter "Activating protective conductor monitor-
ing" on page 45.

Advertisement

Table of Contents
loading

Table of Contents